Ut/uth/uts/uty series drop-in dishware dispensers (9 pages)
Summary of Contents for Wells HD8799
Page 1
Additional manuals are available from your WELLS DEALER. THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any questions concerning installation, operation or maintenance of this equipment.
Page 2
Wells’ discretion have the parts replaced or codes, including incorrect gas or electrical connection. Wells is not liable repaired by Wells or a Wells-authorized service agency.
Page 3
SERVICING INSTRUCTIONS PARTS & SERVICE INTRODUCTION Thank You for purchasing this Wells Manufacturing appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING Electric Shock Hazard Warmer must be properly grounded to prevent possible shock hazard.
Models HD8799 and HD8802 dispensers are equipped with a position. Provided non-skid feet cord and plug. They requires a 115 - 125 volt circuit (50/60 Hz, 2 must be installed at each corner wire plus ground, with NEMA 5-15R receptacle).
Pour product into warming tank. Using pre-heated product will reduce heat-up time. Model HD8799 utilizes a fixed thermostat to hold product at 140ºF (60ºC). NOTE: Product may continue Model HD8802 thermostat may be adjusted to hold to flow for several seconds after product at 170ºF (77ºC) maximum.
CLEANING INSTRUCTIONS PROCEDURE: Clean Heated Dispenser CAUTION: Electric Shock PRECAUTIONS: Disconnect dispenser from electric power. Hazard Drain product and allow dispenser to cool. Do not submerge or immerse FREQUENCY: Daily or after draining product from dispenser in water. dispenser CAUTION: TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Burn Hazard...
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Not plugged in or circuit Restore electric power to warmer breaker off or tripped Power switch not ON Turn power switch to ON Inspect wiring for burnt wires and Internal wiring damage Appliance will not heat proper connections .
SERVICING INSTRUCTIONS ACCESS - BOTTOM PANEL CAUTION Electric Shock All internal components are accessible by removing the bottom Hazard panel. Opening the bottom panel will Remove four screws around the bottom of the warmer tank to expose uninsulated electrical free bottom panel from tank assembly. components.
DRIP TRAY 2L-71747 For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call: Wells Manufacturing 265 Hobson Street Smithville, Tennessee 37166 U.S.A. Service Dept. phone: (314) 678-6314...