AUTO TOTALING TIME CLOCK INSTRUCTIONS
+
Model 5000
/5000
REPLACING RIBBON CARTRIDGE
For optimum performance, the ribbon cartridge should be replaced every 6 months.
A – Ribbon
B – Tab
To remove old ribbon, lift ribbon cartridge straight up using the tab (B) located
on top of cartridge.
Remove new ribbon cartridge from packaging & turn the manual ribbon advance
knob (D) clockwise to straighten ribbon.
Holding tab, install ribbon cartridge into print carriage, making certain retaining
pins (C) are aligned to rear of carriage clips & ribbon (A) is between print head &
metal print mask (see diagram).
Gently push down cartridge until it snaps into carriage while turning the manual
ribbon advance knob clockwise.
Turn manual ribbon advance knob clockwise a few rotations to ensure ribbon is
positioned correctly in front of print head.
Replace the cover & lock unit.
Feed a time card through unit to test print quality.
If time clock prints incomplete characters, the ribbon is not fully installed over
print head. If time clock prints lines that become increasingly light, the cartridge is
not fully snapped into the holder. Reinstall ribbon cartridge, following steps 1-7
until a complete & consistent time card prints.
For assistance, please contact customer support at 888.479.7264 ext 1.
pyramidtimesystem.com
+
HD
C – Retaining Pins
D – Manual Advance Knob
A
B
D
C
REPLACING RIBBON CARTRIDGE
11