Heatilator FL92 Owner's Manual
Heatilator FL92 Owner's Manual

Heatilator FL92 Owner's Manual

Multi-sided woodburning fireplace
Table of Contents

Advertisement

Models:
FL92 Multi-Sided
Woodburning Fireplace
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re. Overfi ring will void your
warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
DO NOT install unvented gas logs.
Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11
NOTICE
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
Hot screen/mesh and glass doors will cause burns.
DO NOT touch screen/mesh or glass doors until
cooled
NEVER allow children to touch screen/mesh or glass
doors
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other
fl ammable materials away.
Installation and service of this fi replace
should be performed by qualifi ed personnel.
Hearth & Home Technologies suggests NFI
certifi ed or factory-trained professionals, or
technicians supervised by an
NFI certifi ed professional.
HOT SURFACES!
Screen/mesh, glass doors
and other surfaces are hot
during operation AND cool
down.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FL92 and is the answer not in the manual?

Questions and answers

Summary of Contents for Heatilator FL92

  • Page 1 For use with solid wood fuel or decorative certifi ed or factory-trained professionals, or gas appliance only. technicians supervised by an • DO NOT install unvented gas logs. NFI certifi ed professional. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 2: Congratulations

    ADJUST DAMPER TO THE FULLY OPEN POSITION. 1915 W. SAUNDERS ST., MT. PLEASANT, IA 52641. Note: An arrow ( ) found in the text signifies change in content.  Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 3: Table Of Contents

    Tools and Supplies Needed E. Contact Information G. Fireplace System Requirements H. Inspect Fireplace and Components Framing & Clearances A. Select Fireplace Location B. Clearances C. Sidewalls/Surrounds D. Frame the Fireplace Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 4: Limited Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645C 12-29-10 Page 2 of 2 Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 6: Listing And Code Approvals

    NOTICE: This fireplace is tested and approved as a decorative fireplace. It should not be factored as a primary heat source in residential heating calculations. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 7: User Guide

    Section 2.D. Section 2.E. Wood Fuel Outside Air Control Section 2.M. Handle Out - Open Handle In - Closed Clear Space Hearth Section 2.L. Figure 2.1 General Operating Parts Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 8: Seasoned Wood

    CAUTION! Odors and vapors released during initial operation may be irritating to sensitive individuals. Open windows for air circulation. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 9: Glass Doors

    HOT when fi replace is in operation. Adjust BEFORE lighting fi re. 48 in. (1219 mm) Front of fireplace to combustible materials Figure 2.3 Clear Space Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 10: Wood Fuel

    Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 11: Maintenance And Service

    Top Cover SCREW Chimney SCREW Slip Section TR11/TR11T TCT1175 ST1175 Terra Cotta Round Termination Cap Square Termination Cap Termination Cap DT SERIES Figure 3.1 Chimney & Termination Cap Cleaning Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 12: Check Firebox Refractory

    • Light deposits Use household glass cleaner • Heavy deposits Use wood ash on damp cloth or, Use commercial fireplace glass cleaner (consult with your dealer) Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 13: Troubleshooting Guide

    Add glass doors to slow down air flow. Overdrafting Check for correct vent height; too much vertical height creates overdrafting. Check location of vent termination (refer to chimney assembly section). Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 14: Getting Started

    (Section 11) Hearth extension Outside (Section 11) combustion air Factory-built fireplace (Section 7) Protective metal hearth strip(s) (Section 7) Figure 5.1 Typical Fireplace System Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 15: Design And Installation Considerations

    Tight sealing construction of the structure • Mechanical exhausting devices NOTICE: Hearth & Home Technologies Inc. recommends • Improper location of the chimney the use of direct vent fireplaces in basements. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 16: Locating Fireplace & Chimney

    • Below adjacent structure • Insulated exterior chase • Lower roof line • Avoid outside wall in cooler climates Windward Leeward Multi-level Roofs Figure 5.2 Recommended Chimney Locations Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 17: Tools And Supplies Needed

    Hearth Extension (required, sold separately) • Outside Air Kit Duct (required for outside air installation, sold separately) • Chimney System (required, sold separately) • Termination Cap (required, sold separately) Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 18: Framing & Clearances

    56 in. (1422 mm) • Clearances • Mantel Projections • Fireplace Dimensions HEARTH EXTENSION (shaded) 64 in. (1626 mm) Figure 6.1 Fireplace Locations Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 19: Clearances

    0 in. to level of standoffs 1/2 in. (13 mm) to back of appliance 48 in. 1219 mm 0 in. to floor Figure 6.2 Air Space Clearances Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 20: Sidewalls/Surrounds

    42-1/2 in. 36 in. min. (1080 mm) (914 mm) 47-1/8 in. (1197 mm) header height. Use only non-combustible material below the standoffs. Figure 6.4 Framing the Fireplace Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 21: Installation Of Fireplace

    • Check fireplace opening for square to ensure proper fit of glass doors. Measure diagonals of fireplace opening to make sure they are equal. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 22 Figure 7.4 Outside Combustion Air Placement Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 23: Install Outside Air Kit

    • Assemble flexible duct (not supplied) between the door assembly and the inlet tube assembly. Secure it in position with the supplied wire ties. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 24: Chimney Assembly

    Ceiling firestops are required where chimney passes through ceiling or floor Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 25: Chimney Requirements

    20 ft. (5.03 m) min. height/double offset-return (1118 mm) SL1136 34-3/4 90 ft (27.43 m) max. height Effective Height SL1148 46-3/4 1187 * Dimensions reflect effective height. Figure 8.2 Chimney Requirements Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 26: Using Offsets/Returns

    98 7/8 2511 Proper assembly of air cooled chimney parts results in an overlap of chimney joints of 1-1/4 in. (32 mm). Effective length is built into this table. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 27: Assemble Chimney Sections

    • Vertical straight runs of chimney must be supported every 35 ft (10.7 m). D. Install Chimney Air Kit Follow instructions provided with this accessory. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 28: Install Ceiling Firestops

    (use 600° F sealant). Catalog # FS538 FS540 Figure 8.5 Installing the Ceiling Firestop Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 29: Install Attic Insulation Shield

    17 in. (432 mm) diameter 6 Tabs bent in 90° Insulation Insulation 13 in. Ceiling Firestop Pipe (330 mm) Figure 8.8 Install Attic Insulation Shield (firestop below ceiling) Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 30: Cut Out Hole In Roof

    • Caulk the flashing plate and roof junction as well as the vertical seam on the flashing. All nail heads must be caulked with a roofing sealant. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 31: Chimney Termination Requirements

    In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. Figure 8.10 Multiple Chimney Locations Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 32: Chase Installations

    False Ceiling False Ceiling • Failure to prevent contact between insulation or other Chimney materials and chimney system may cause overheating and fire. Figure 9.1 Chase Assembly Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 33: Install Fireplace & Chimney

    WARNING! Risk of Fire! DO NOT caulk the pipe to the Galvanized chase top collar. Chase Top • Caulk all seams to prevent leaks. • Refer to Figure 9.3. Figure 9.3 Chase Top Construction Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 34: Install Termination Cap

    4 3/4 in. (121 mm) maximum Chase Chimney Pipe Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.6 Installing an ST1175 Square Termination Cap Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 35 2 in. (51 mm) 7 in. (178 mm) Chase Chimney Pipe Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.7 Installing a TCT1175 Terra Cotta Cap Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 36: Shrouds

    23 x 23 737 x 737 584 x 584 Min. Opening Width 26 x 26 20 x 20 660 x 660 508 x 508 Figure 10.2 Open Top Shroud Dimensions Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 37 34 x 34 34 x 34 864 x 864 864 x 864 Min. Height Above Radiation Shield Min. Opening Width Min. Opening Height Figure 10.4 Roofed Style Shroud Dimensions Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 38: Finishing

    5-1/8 in. Common Brick 0.20 5-1/8 in. Ceramic Tile 12.50 0.08 12-1/4 in. Armstrong™ Privacy Guard Plus 0.46 2.18 1/2 in. Marble 14.3-20.0 0.07-0.05 14-5/8 in. - 20-3/8 in. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 39 Protective insulation Metal Hearth (see Table 11.2) Strip 2 in. (51 mm) required Floor constructed of wood or other combustible material Figure 11.1 Hearth Extension Dimensions Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 40: Finishing Material

    2 in. (51 mm) Figure 11.3 Decorative Facing Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 41: Combustible Mantel

    [1016 mm] [1016 mm] BRICK FRONT FRONT 12 in. 12 in. [305 mm] [305 mm] Figure 11.5 Mantel Leg or Wall Projections (acceptable on both sides of opening) Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 42: Accessories

    Repack beyond 4 in. (102 mm) insulation from fireplace side. knockout 4 in. (102 mm) Figure 12.1 Gas Line Installation Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 43: Reference Materials

    20 in. (SIDE OF FIREPLACE) (508 mm) HX4 Hearth Extension 1/2 in. AK17/AK18 (13 mm) Outside Air Kit See your Heatilator dealer for a complete listing of optional components. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 44: Chimney Components

    Inside Diameter 20-3/4 in. 11 in. (527 mm) (279 mm) Outside Diameter 13 in. (330 mm) SL11 Vent Stabilizer Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 45 15-3/4 in. (400 mm) 13 in. (330 mm) TR11 - Round Termination Cap CB576 Chimney Joint Band 10 3/4 in. 26 in. TR-TVK TR Top Vent Kit CT-11A Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 46 72 in. 36 in. DTO134 (1829 mm) (914 mm) 13-3/8 in. (340 mm) DTO146 22.7 1168 DTS134 21.18 2 in. (51 mm) DTS146 21.18 1168 CT56 Chase Top Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 47: Service Parts

    FL92 D. Service Parts Beginning Manufacturing Date: Oct. 2001 Multi-Sided Woodburning Fireplace Ending Manufacturing Date: Active Part numbers on following page. Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 48 Outside Air Handle 17333 Refractory Retainer 11847 Refractory Standoff 13327D Side Refractory Bracket Qty. 2 req. 13328 Strip Protectors Qty. 2 req. 18320 Installation Instructions & Owner's Manual 34955 Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...
  • Page 49: Contact Information

    Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev Z 1/11...

Table of Contents