2. At the junction box, cut the cord. Be sure to leave at least six (6) inches of cord for
making connections.
3. Carefully strip the outer cord jacket to expose six (6) inches of the underlying three
insulated wires.
4. Connect these three (3) wires to their corresponding junction box circuit wires and
secure the junction box cover in place.
WARNING! Do not operate this light for more than two minutes without
completely submerging it in water. Failure to do so can result in permanent
damage to the light. If the light is operating without being fully submerged in water,
the light's circuitry will automatically shut down for a cooling period before powering
back on within 10 minutes to prevent damage to the light.
5. Using the stainless steel pilot screw provided, install the Color Splash light assembly
into the niche, carefully tightening the pilot screw. (Reference Figure 1)
WARNING! Use only the stainless steel pilot screw provided with this
underwater light.
This special pilot screw secures and electrically grounds the fixture to the mounting
ring and wet niche. Failure to install the stainless steel pilot screw provided could
create an electrical shock hazard, resulting in death or serious injury to pool users,
installers or others.
6. Fill the pool to completely submerge the light prior to operating the light. Do not
operate light out of water, this may cause damage to the light.
7. Make a final check to confirm proper light operation by switching "on" the main
switch or circuit breaker and the light switch. The light should illuminate when
power is switched "on". If the light is not operating, go back to Step 1 to recheck each
installation step for proper completion.
pg 4
Need help?
Do you have a question about the Color Splash and is the answer not in the manual?
Questions and answers
Pool light and spa light don’t match. Now spa light out. Pool light working perfectly.
The J&J Electronics Color Splash pool and spa lights may not match if they are not on the same electrical circuit. The lights are “synchronous,” meaning they will display the same light shows only when connected to the same circuit.
The spa light may not be working due to improper installation, power not being switched “on” at the circuit breaker or light switch, or failure to follow correct wiring procedures. It is also important to ensure the light is submerged in water during operation, as running it dry can cause the light to shut down or become damaged.
This answer is automatically generated