Vent Pipe Connection To Blower; Different Coupling Installations According To Vent Sizes - State Water Heaters GS6 40 YBVIS Installation And Operating Manual

Power vented gas models with hot surface ignition
Table of Contents

Advertisement

3" MIN.
LENGTH
A VENT USED IN A
SPECIAL VENTING
SYSTEM WITH POSITIVE
VENT PRESSURE AND
PASSING THROUGH A
ROOF SHALL EXTEND AT
LEAST 18" ABOVE THE
HIGHEST POINT WHERE
IT PASSES THROUGH THE
ROOF SURFACE AND ANY
OTHER OBSTRUCTION
WITHIN A HORIZONTAL
DISTANCE OF 18". A
VERTICAL VENTING
SYSTEM MUST BE
SUPPORTED EVERY 5 ft..
Figure 36.

Vent pipe connection to blower

1. The plastic vent piping connects into the rubber
coupling located on the top of the blower assembly.
This coupling includes gear clamps to connect the
venting to the blower. These connections must be
properly seated and tightened to prevent the leakage
of fl ue gases into the area. See Figure 37 thru Figure
41.
2. The 40, 50 and 60-gallon heaters with rated inputs of
50k Btu/hr or less are designed and supplied with a
2" rubber coupling to accept the vent pipe.
3. The 50 and 75-gallon models with rated inputs of 60k
Btu/hr or more are supplied with a 3" rubber coupling
to accept the vent pipe. Note: Polypropylene vent
systems require separate adaptor.
4. Before installing clean and lightly sand the end of the
PVC/CPVC plastic vent piping that will connect into
the rubber coupling. For polypropylene vent systems
follow manufacturer's instructions.
5. Loosen the upper clamp on the rubber coupling and
insert the sanded end of the vent piping a full 1-1/4".
Do not use glue or sealant in the rubber coupling.
Check that there is no stress on the connection or the
vent piping that may be caused by twisting or bending.
6. Tighten the upper clamp so that the vent piping is
fi rmly secured in the coupling and is gas tight. Do not
over tighten or cause distortion of any of the parts.
Ensure the bottom of the rubber coupling is fi rmly
seated on the blower outlet and that the lower gear
clamp is also secure. Check to ensure there is no
distortion or movement of the clamped assembly once
it is completed.
CAUTION
Property Damage Hazard
• Do not overtighten the top and bottom gear clamps of the
rubber coupling.
• Do not apply solvent cement or silicone to the rubber
coupling connection.
34
TERMINATION
MAY BE 90°
ELBOW
18" OR
RODENT
ABOVE
SCREEN
ANTICIPATED
(INSTALL
SNOW LEVEL
INTO
ELBOW)
ROOF
LINE
www.statewaterheaters.com
Different coupling installations according to vent
sizes
CONFIGURATION
FOR 40, 50 AND
60-GALLON (LO-
INPUT) HEATERS
CONNECTED TO
2" VENTING.
2" RUBBER
COUPLING
(SUPPLIED)
BLOWER
Figure 37.
CONFIGURATION
FOR 40, 50 AND
60-GALLON (LO-
INPUT) HEATERS
CONNECTED TO
3" VENTING.
2" RUBBER
COUPLING
* FOR 3" DIRECT
(SUPPLIED)
CONNECTION TO
THE BLOWER,
ORDER
COUPLING Kit #
9008311005
(SEE ALSO Figure
BLOWER
41).
Figure 38.
CONFIGURATION
FOR LO-INPUT
3" RUBBER
HEATERS
COUPLING
CONNECTED TO
(ORDER COUPLING
4" VENTING.
Kit # 9008311005
TO REPLACE 2"
LOW-INPUT
RUBBER COUPLING
HEATERS ARE
SUPPLIED.)
SUPPLIED WITH
A 2" RUBBER
COUPLING.
BLOWER
Figure 39.
CONFIGURATION
FOR HI-INPUT
HEATERS
CONNECTED TO
3" VENTING.
3" RUBBER
COUPLING
(OPTIONAL
(SUPPLIED)
CONFIGURATION
FOR LO-INPUT
HEATERS
CONNECTED TO
3" VENTING.)
BLOWER
Figure 40.
2" VENT
PIPE
3" VENT
PIPE
2"-3"
ADAPTER*
(FIELD
SUPPLIED)
2" VENT PIPE,
75mm (3 in.)
MAX LENGTH
4" VENT
PIPE
3"-4"
ADAPTER
(FIELD
SUPPLIED)
3" VENT PIPE,
3 in. MAX
LENGTH
3" VENT
PIPE

Hide quick links: