WATER PIPING - MIXING VALVE USAGE

Mixing Valves

DANGER
HOT
HOT
BURN
Water heated to a temperature which satisfi es space
heating, clothes washing, dish washing, and other
sanitizing needs can scald and cause permanent injury
upon contact. Short repeated heating cycles caused by
small hot-water uses can cause a temperature increase of
the hot water by 20F° higher than the heater's temperature
settings.
SUGGESTED PIPING
TEMPERED
ARRANGEMENT FOR
POTABLE WATER
TOP CONNECTIONS
MIXING VALVE
TEMPERATURE-
PRESSURE
RELIEF VALVE
* NOTE: THE
T&P VALVE
DISCHARGE
PIPE MUST
BE PIPED
DIRECTLY TO
THE DRAIN
OR EXTERNAL
TO THE
BUILDING
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
GAS
SUPPLY
6" MAX.
AIR GAP*
MASSACHUSETTS: INSTALL A VACUUM RELIEF IN COLD WATER LINE
PER SECTION 19 MGL 142.
Figure 8.
Water temperature over
125°F can cause severe
burns instantly resulting in
severe injury or death.
Children, the elderly and the
disabled and are at highest
risk of scald injury.
Feel water before bathing or
showering.
Temperature limiting devices
such as mixing must be
installed when required by
codes and to ensure safe
temperatures at fixtures.
SHUT-OFF
VALVE
COLD-WATER
INLET
CERTAIN
MODELS ARE
EQUIPPED WITH
SIDE PLUMBING
CONNECTIONS
FOR SPACE
HEATING. THE HOT
AND COLD FITTING
ASSEMBLIES
(PART #9001262)
CAN BE ORDERED
THROUGH THE
MANUFACTURER
METAL DRAIN
PAN 1.75"
MAX. DEPTH.
AT LEAST 2"
GREATER THAN
THE DIAMETER
OF THE WATER
HEATER.
DRAIN
VALVE
www.statewaterheaters.com
his appliance has been design certifi ed as complying
with American National Standard/CSA Standard for water
heaters and certain models with side plumbing connections
are considered suitable for Water (Potable) Heating and
Space Heating. Note: Do not use in space heating only
applications.
The water supply pressure should not exceed 80 psi. If this
occurs, a pressure reducing valve with a bypass should be
installed in the cold water inlet line. This should be placed
on the supply to the entire house in order to maintain equal
hot and cold water pressures.
SUGGESTED PIPING
TEMPERED
ARRANGEMENT FOR
POTABLE WATER
TOP CONNECTIONS
NON-TEMPERED
WATER SUPPLY
MIXING VALVE
MASSACHUSETTS:
INSTALL A VACUUM
RELIEF IN COLD
WATER LINE PER
SECTION 19 MGL
142.
GAS
SUPPLY
DRAIN
VALVE
METAL DRAIN
PAN 1.75" MAX.
DEPTH. AT
LEAST
2" GREATER
THAN THE
DIAMETER OF
THE WATER
HEATER.
Figure 9.
SHUT-OFF
VALVE
COLD-WATER
INLET
NON-TEMPERED
WATER RETURN
TEMPERATURE-
PRESSURE
RELIEF VALVE
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
* NOTE: THE
T&P VALVE
DISCHARGE PIPE
MUST BE PIPED
DIRECTLY TO
THE DRAIN OR
EXTERNAL TO
THE BUILDING
6" MAX.
AIR GAP*
11