Safety Devices; Service Functions; Parameters Programming Function - BaltGaz NEVALUX-8230 User Manual

Wall-hung combi gas boiler with forced heat carrier circulation
Table of Contents

Advertisement

13.2.6. Safety devices

Device
Safety catch 21 ( see Annex III, page 66)
Pressure sensor 14
Thermorelay 15
Bypass valve 20
Safety valve 22
Air outlet valve 8
Gas supply regulator 9
Ionization plug 6
Air pressure switch 27

13.3.Service functions

13.3.1.Parameters programming function

The parameters programming function permits to change the main launch and operation parameters of the boiler.
This function works only in the standby mode and permits to change the following parameters:
"P0" – ignition power 0 - 99 (100 steps);
"P1" – minimal heating power 0 - 39 (40 steps);
"P2" – maximum heating power 40 - 99 (60 steps);
"P3" – minimal time from switching off to the next putting into operation 0 - 14 (min). Factory settings:
Parameter
P0
P1
P2
P3
For using the parameters programming function it is necessary to:
1) Switch the boiler off, consequently pressing the button К5 (see Scheme 3, page 8) until the symbol
appears on the boiler's display.
2) Disconnect the boiler from the power line;
3) Connect the boiler to the power line again. For 5 seconds there is a possibility to activate the programming
function;
4) Press and simultaneously hold the DHW and heating temperature reduction buttons (К2 and К4) for activating
the parameters programming function;
5) Quit hold of the buttons, when the code "P0" and the symbol
6) Choose the parameter that must be changed, pressing the buttons КЗ or К4;
7) Press the button К5, in order to see the parameter value on display. The symbol
flickering;
8) Change the chosen parameter's value, pressing the buttons К1 (value increase) or К2 (value reduction). In
order to increase speed of parameter changing you may press and hold the buttons К1 or К2;
9) Press the button К5, in order to keep the set parameter value and return to choosing parameters;
10) Repeat the cycle, beginning from point 6, in order to modify all parameters that you want to change;
11) Press the button К6 (RESET) in order to exit the programming mode.
Do not change the parameter Р3 with no extreme need.
For control
Protecting the electronic board and electric circuits from the power line
surcharge and short circuit
For the heat carrier
Minimal heat carrier pressure control and control of absence of air in the
heating system
Protecting primary heat exchanger from overheating
Protecting primary heat exchanger from overheating at increased
resistance in the heating system
Spilling the heat carrier from the heating system when the pressure is
higher than 3 bar
Automatic air removal from the heating system
For gas
Ignition at reduced pressure in order to avoid the "clap". Blocking gas
supply when a dangerous situation appears (heat carrier overheating,
absence of draught etc.)
Burner flame control.
Cease of gas supply to the burner when there is no flame
For combustion products
Fan operation control.
Cease of boiler operation in case of no draught or the fan's breakdown
Natural gas
40
0
99
3
29
Purpose
Technical staff manual
Liquefied gas
60
0
99
3
Technical staff manual
appear on display;
on display will start

Advertisement

Table of Contents
loading

Table of Contents