PKFY-P12NHMU-E2 – DIMENSIONS
Model:
Left side
D
Knock out hole
for left piping
Sleeve
Through hole
(purchased locally)
~
~
2-1/2
3-1/8
2-1/2
3-1/8
~
~
( 65
80)
( 65
80)
Knock out hole
for lower piping
77- 3/16( 5.1)
Tapping
screw hole
0
5/8(16)
1-1/16(28.5)
1-9/16(41)
3-1/16(78.5)
3-9/16(91)
4-1/16(103.5)
4-9/16(116)
6-1/2(166)
7(178.5)
8(203.5)
9-1/8(232.5)
9-15/16(253.5)
Wall hole
for
left rear
piping
Knock out hole for piping
C
7/16(12.5)
2-3/16(56)
A
1-3/4(46)
1-11/16(43)
2-5/16(60)
Mitsubishi Electric Air Conditioning & Refrigeration Systems Wo rks acquired ISO
based on a review of quality warranties for the production of refrigeration and air
conditioning equipment.
ISO Authorization System
The ISO 9000 series is a plant authorization system relating to quality warranties as
development, production, installation and auxiliary services" for products built at
an authorized plant.
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmental
The ISO 14000 series is a set of standards applying to environmental protection set by the
International Standard Organization (ISO).
15-3/16(387)
7-1/2(192)
23-9/16(599)
2-1/8
27-1/16(688)
(55)
35-5/16(898)
Front side(Grille open)
17-15/16(457)Gas pipe
21-3/16(539)Liquid pipe
24(610)Drain hose
Under side
Vane(auto)
24-1/16(612)
Louver(manual)
Knock out hole
C
for lower piping
Center measurement hole 3/32( 2.5)
4- 5/16( 9) Bolt hole
Knock out hole for
left rear piping
2-3/4×12-3/16(70×310)
Required space(Indoor unit)
D
1-11/16(43)
Min.1-31/32(50)
B
Top side
Unit : in(mm)
Mount board
Front side
Right side
9-3/4(249)
6-1/16(155)
Knock out hole
for right piping
Terminal block for power supply
Terminal block for transmission
Terminal block for
MA-remote controller
6-5/8(169)
Emergency operation switch
6-3/16(158)
(cooling/heating)
7-3/16(184)
DEFROST/STAND BY lamp
Operation lamp
Refrigerart
Liquid pipe
1/4F ( 6.35)
Piping
1/2F ( 12.7)
Gas pipe
Drain hose
5/8 ( 16) I.D
Receiver
B
Mount board
Indoor unit outline
13/16(21.8)
0
3/4(20)
1-1/4(32.7)
2-1/16(53.5)
2-9/16(66)
5(128.5)
6(153.5)
9-1/16(231.5)
10-3/4(273.2)
Wall hole for
right rear piping
(mm)
Air inlet
Air inlet
Air outlet
Min.8-5/8
Min.5-7/8(150)
(220)
Mitsubishi Electric Sales Canada Inc.
www.MitsubishiElectric.ca
Specifications are subject to change without notice.
SB_PFY-P12NHMU-E2_201205
A
3/16(5)

Advertisement

loading