Battery Charging And Back Up; Trouble Shooting - Samlexpower SEC-1212 Owner's Manual

Desktop switching power supplies
Table of Contents

Advertisement

BATTERY CHARGING AND BATTERY BACK-UP
!
WARNING ! THESE UNITS ARE POWER SUPPLIES AND
NOT BATTERY CHARGERS. DO NOT CONNECT THESE UNITS DI-
RECTLY TO A BATTERY
These units should NOT BE DIRECTLY CONNECTED TO A BATTERY
for charging or for battery back-up. Battery charging and battery back-up
may be undertaken only when the battery is connected through suitable
external isolating diodes and charge limiting resistor. The isolating diode
will ensure that the battery does not back power the power supply. When
a battery is deeply discharged, it will initially draw a very large charging
current and thus, will force the power supply into current limit mode for
prolonged periods. This is harmful for the power supply. The charge
limiting resistor will limit the charging current, thereby, ensuring that the
maximum charging current is well below the current limit value of the
power supply. It is recommended that optional battery back-up
module BBM-1225 may be used to convert SEC-1212/SEC-1223 for
battery back-up application.
TROUBLESHOOTING - GENERAL
PROBLEM : Power ON/OFF switch does not illuminate when turned on.
PROBABLE CAUSE
No power in the AC outlet
AC side fuse inside the power
supply is blown
PROBLEM : AC side fuse blows as soon as power is turned on.
PROBABLE CAUSE
Unit is defective
SUGGESTED REMEDY
Check there is power in the outlet.
Replace the fuse inside the unit.
See fuse ratings at page 11
SUGGESTED REMEDY
Call technical support.
5.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sec-1223

Table of Contents