At the end of the boot up, the water temperature will be displayed. If
the temperature is below 100˚F (38˚C), the low speed pump and the
heater will turn on until the temperature rises to the preset 100˚F (38˚C).
Approximately two minutes after the system has been initially powered
up, the first filtration cycle will begin to operate. Any time after the boot
up, you will be able to select a pre-programmed filter cycle and reset your
temperature set point.

FILTRATION

Proper filtration is an important key to maintaining the clarity of your hot
tub's water. The Filtration system is designed for unsurpassed effective-
ness at removing debris and suspensions from the water anytime the
water is circulating.
You may change the filtration cycle start time by one of the following meth-
ods:
1. Turn power to the hot tub off and then back on at the breaker, or
2. Press and hold for three seconds the "WARMER" and "COOLER"
buttons at the same time. When the currently set cycle appears (F1-
F6) press the jets 1 button one time and the control will go into the
initial power up routine.
Example: If you want your first filter cycle start time to be at 4 PM, perform
above functions just before the desired start time. Filter cycle start time
may vary slightly.
Your hot tub comes with six pre-programmed filtration cycles (F1-F6) and
two lockout modes (L1-L2). Of the six filter cycles, three cycles are in the
standard mode and three cycles are in the economy mode.
To change the filter cycles, press and hold the"WARMER" button and
"COOLER" buttons for 3 seconds. This will get you into the filter cycle pro-
gramming mode. Use the "WARMER" and "COOLER" buttons to scroll
between F1 and L2. This numeric value coincides with a specific filter
cycle that is to be used for filtration.

STANDARD MODE

Heating is automatically controlled by the loss of water temperature. If
the hot tub water drops 2˚F (1.2˚C) below the set temperature, the low
speed pump and the heater will automatically turn on. They will both
remain on until the water temperature reaches the temperature setpoint.