Thermo Pride OH6FA072D48B Installation And Operation Manual page 31

Oil fired furnace
Table of Contents

Advertisement

Heating Speed Set-ups
OH6FA072DV4
BTUH
Fan
Control
SW 1
Switch
Heating
Settings
CFM
3-OFF
740
2-OFF
1-OFF
3-OFF
812
2-OFF
1-ON
3-OFF
883
2-ON
1-OFF
Factory
SW1
3-OFF
968
Switch
2-ON
Settings
1-ON
3-ON
1054
2-OFF
1-OFF
3-ON
1153
2-OFF
1-ON
3-ON
1267
2-ON
1-OFF
3-ON
1424
2-ON
1-ON
= Recommended Heating Speed Setting
Low Fire
Med Fire
60,000
72,000
Aprox. Rise
Aprox. Rise
Aprox. Rise
0
0
(F
)
(F
)
(F
o
75
o
o
68
82
o
o
63
76
o
o
57
69
o
63
o
58
Figure 18-1: ECM blower motor speed chart
28
Furnace Motor Current
Draw (Amps/ / Watts) vs.
External Static Pressure (in W.C.)
High Fire
90,000
0
)
0.2
0.9/75
1.4/123
1.0/86
1.5/136
1.1/95
1.6/143
o
86
1.2/110
1.8/165
o
79
1.4/128
2.0/183
o
72
1.7/153
2.4/221
o
66
2.1/192
2.7/252
o
58
2.8/263
3.4/325
0.4
0.6
1.7/156
1.9/172
2.2/199
2.5/233
2.6/244
2.9/267
3.2/310
4.1/394