OIL FIRED FURNACE INSTALLATION AND OPERATION MANUAL WITH USERS INFORMATION SECTION MODELS: OL20FA151T60(B/R) OL20RA151T60(B/R) c WARNING : IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
CAUTION: Do not exceed 90° rotation of the flue elbow counter clockwise right from the vertical positon. See Page 2. cWARNING: The predetermined fan and limit locations on all of the Thermo Pride oil fired furnaces have been tested and approved by Thermo Products, LLC. in conjunction with Underwriters Laboratories, Inc.
Page 4
All installations and services must be performed by qualified service personnel. This page contains reproductions of the various instruction and warning labels placed on the Thermo Pride Oil Furnaces. Please read and comply with the contents of these labels.
Page 5
All installations and services must be performed by qualified service personnel.
All installations and services must be performed by qualified service personnel. TABLE OF CONTENTS SECTION BEGINNING PAGE I. SAFETY SECTION II. GENERAL INSTRUCTIONS A.VENTING B. DUCT WORK/AIR CONDITIONING C. BURNER INSTALLATION D. FUEL SYSTEM INSTALLATION E. WIRING III. STARTING THE UNIT A.
All installations and services must be performed by qualified service personnel. II. GENERAL INSTRUCTIONS - READ BEFORE START OF INSTALLATION 1. The heating output capacity of the furnace proposed for installation should be based on a heat loss calculation made according to the manuals provided by the Air Conditioning Contractors of America (ACCA) or the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc.
The OL20 furnace is to be installed on non-combustible flooring only. NOTE: When power venting a Thermo Pride oil fired furnace an isolated combustion air kit (PVB or Beckett boot) is to be used with the other manufacturers power venting system.
All installations and services must be performed by qualified service personnel. TABLE 1: Suggested sizes and positions of flue pipe opening on left hand side of casing. UNIT DIA. “X” “Y” FLUE DIA. GASKET TRIM COLLAR HOLE DIM. DIM. PART# PART# OL20FA151T60 7-1/2”...
All installations and services must be performed by qualified service personnel. The most common location for the A-shaped coil (A style) is shown in Fig. 2. Fig 2: Acceptable locations for the air conditioner evaporator coil. NOTICE: The minimum coil pan clearance for a sectional or drum type heat exchanger is three inches unless specified otherwise by the individual coil manufacturer.
Page 11
Thermo Pride burners. (See Fig. 5). See Thermo Pride burner application chart for type of insulator. Do not allow the burner tube or end cone to physically touch or protrude into the chamber, as excess heat transfer could result in destruction of the tube, end cone or both.
All installations and services must be performed by qualified service personnel. Fig. 5: (Side view) Burner insertion illustration D. FUEL SYSTEM INSTALLATION In situations where the oil storage tank is installed at the same level with, or above, the burner, a single oil supply line run from the oil tank to the burner will be usually be adequate.
All installations and services must be performed by qualified service personnel. III. STARTING THE UNIT A. INITIAL OPERATION OF THE FURNACE WARNING: To avoid possible explosion, DO NOT attempt to light the burner if: 1. Oil has accumulated in the base of the combustion chamber. 2.
All installations and services must be performed by qualified service personnel. to obtain the correct overfire draft reading. See table 2. The draft measured at the flue (stack draft) should read no more than 0.05 in. W.G. NOTICE: The overfire draft is the more important measurement and should be used to adjust the setting of the barometric draft control.
B. LIMIT POSITION AND LOCATION cWARNING: The predetermined fan and limit locations on all of the Thermo Pride oil fired furnaces have been tested and approved by Thermo Products, LLC. Any attempt to relocate these safety controls or replace these safety controls with a control that is not approved, or is incompatible, may result in personal injury, substantial property damage or death.
All installations and services must be performed by qualified service personnel. Fig. 6: Typical Heat Exchanger Cleanout Cover Locations. With access to the inside of the heat exchanger through the burner area, clean-out openings, and vent pipe connection, it is possible to use a long, flexible wire brush and an industrial type vacuum cleaner to remove any soot build-up.
All installations and services must be performed by qualified service personnel. The sequence of operation of the furnace. The correct operation and maintenance of the appliance as outlined in the users information manual. That failure to maintain and operate this furnace in accordance with these instructions could result in hazardous conditions, bodily injury, property damage and may void the limited warranty on the furnace.
All installations and services must be performed by qualified service personnel. cCAUTION: Do not attempt to make repairs yourself. cWARNING: The area around the furnace should be kept free and clear of combustible liquids and material, especially papers and rags. cWARNING: never burn garbage or refuse in your furnace.
Page 19
All installations and services must be performed by qualified service personnel.
All installations and services must be performed by qualified service personnel. APPENDIX-A Replacement Parts List Replacement Parts for OL20FA151T60...
Page 21
All installations and services must be performed by qualified service personnel.
Page 22
All installations and services must be performed by qualified service personnel. Replacement Parts for OL20RA151T60...
Page 23
All installations and services must be performed by qualified service personnel.
Page 24
All installations and services must be performed by qualified service personnel. Replacement Parts for Beckett Burner...
Page 25
All installations and services must be performed by qualified service personnel. Replacement Parts for Riello F5 Burner...