Bunn SRU Operating & Service Manual page 12

Coffee brewer
Table of Contents

Advertisement

TROUBLESHOOTING (cont.)
PROBLEM
Circuit breaker keeps tripping
Water keeps running from swing
spout
Inconsistent coffee yield
Funnel overflows
PROBABLE CAUSE
1. Circuit Breaker
2. ON/OFF Switch
3. Brew Circuit
4. Refill Circuit
1. Timer
2. Start Switch
1. Timer
2. Solenoid Valve
3. Lime build-up in swing spout and
pump tubing.
1. Filters
2. Hole in bottom of funnel
obstructed.
3. Pump - Flow Rate
Page 12
REMEDY
Refer to Service - Circuit Breaker for
testing procedures. See page 15
Refer to Service - ON/OFF Switch for
testing procedures. See page 23
Refer to Service - Pump Assembly for
testing procedures. See page 24
Refer to Service - Liquid Level
Board for testing procedures. See
page 21
Refer to Service - Timer for testing
procedures. See page 31 or 33
Refer to Service - Start Switch for
testing procedures. See page 29
Refer to Service - Timer for testing
procedures. See page 31 or 33
Refer to Service - Solenoid Valve for
testing procedures. See page 26
Remove swing spout and insert
deliming rod down into pump tubing
as far as possible.
Use Bunn
filters made for the SRU
®
brewer.
Remove obstruction.
Check pump flow rate with a watch.
Pump flow rate should be approxi-
mately 24 ounces in 15 seconds. Be
sure pump assembly is free of any
obstructions.
10067 080200