5' whirlpool, integral apron with removable access panel high gloss acrylic shown less all fittings

Advertisement

Quick Links

WILLIAMSBURG
ELITE™ 5'
INTEGRAL APRON WITH
REMOVABLE ACCESS PANEL
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
12
(305mm)
10-1/4
(260mm)
3/4
(19mm)
FINISHED
WALL
SEE FITTING
SPECS FOR
DIMENSIONS
9
(229 mm)
32
(813mm)
CUTOUT IN FLOOR FOR DRAIN
C/L OF
3
SUPPLIES
(76mm)
C/L OF DRAIN
OPTIONAL TO
FINISHED FLOOR
1" WATER
USUALLY BETWEEN
RETENTION
65 & 78
FLANGE
(1651 & 1981mm)
(3 SIDES)
C/L OF
OVERFLOW
3-1/2
(89mm)
TOP OF
DECK
21-1/2
(546mm)
ROUGH
FLOOR
BATH
SUPPORT
MATERIAL
1-1/2 O.D.TAILPIECE
Left-hand version shown
GENERAL SPECIFICATIONS FOR 2425E WHIRLPOOL
INSTALLED SIZE
60 x 32 x 21-1/2 (1524 x 813 x 546mm)
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
3
CUBE (FT
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP
General Installation Information
Bath may only be installed in a recess type installation.
Locate studs as required. insure rough dimensions are proper, plumb and square. For whirlpools, access to pump/motor may be made
through access opening in apron panel. The following procedure must be used for all installations: leveling support stringer should be as
indicated.
this bath is not self-supporting and must be supported along it's entire bottom. Support with mortar or grout. Position
bathtub/whirlpool within the recess, check level, front to back, side to side, and shim as necessary. To secure the tub to wood studs use
drywall screws w/washers or roofing nails immediately above the flange of the tub.To secure the tub to steel studs use 4" drywall screws and
flatwashers.
See page 2 for complete installation information.
Caution: Take extra care when driving nails or screws to avoid damaging the tub. The tile or similar finished floor will be butted against
the bottom of the tub apron, also holding the tub in place.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
752876-100 Rev. E
2425E-LHO
2425E-RHO WHIRLPOOL

INSTALLATION INSTRUCTIONS

60
(1524mm)
WATER
RETENTION
FLANGE
(8) JETS
(3 SIDES)
(406mm)
PUMP
ACCESS TO PUMP/MOTOR
(2) AIR VALVES
THROUGH REMOVABLE
FRONT ACCESS PANEL
C/L OF
SHOWER ARM
FINISHED
WALL
IN-LINE HEATER
REMOVABLE
C/L OF
BLANK
VALVES
C/L OF
12
SPOUT
(305mm)
OPT.
4
TILING
LEVELING STRINGER
(102 mm)
FLANGE
NOT FOR SUPPORT
UNDERSIDE
OF DECK
21-1/4
(540mm)
REF.
DIM
1-1/2 N.P.T.M.
THREADS
2-3/4
(70mm)
4-5/8
(117mm)
115 Lbs. (52 Kg.)
574 Lbs. (258 Kg.)
55 Gal. (208 L.)
45 Gal. (171 L.)
16-1/4 x 38-1/4 (413 x 972mm)
26-1/4 x 52-1/2 (667 x 1334mm)
15 (381mm)
43 Lbs./Sq.Ft. (208 Kgs./Sq.m)
20.8
35.3
1.6 HP, 9.7 AMPS,120V.

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to
you after careful inspection. the whirlpool version is completely
assembled with pump, motor, and system piping. All you need to finish
the installation are your selected fittings and electrical connections for
a whirlpool. To insure maximum performance and pleasure from this
16
product, please follow the instructions and cautions.
List of Optional Components (not included):
• Flex-Jet Pulse Jet Kit*
ON/OFF
SWITCH
• Flex-Jet Soft Jet Kit*
• E-Z-Install Heater*
List of Required Components (not included):
• Drain*
* see your Home Depot Retailer
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
General Installation Information
Carefully uncrate and inspect your new bath for any shipping damage.
If such damage is found, report it to your vendor immediately. After
inspection and during installation, protect the bath from construction
damage. Before installation, and before enclosing with wallboard,
tile, etc., water test the unit and check for leaks. Do not make
modifications to the whirlpool system or remove pump from factory
mounting. This could adversely affect the safety and performance of
the whirlpool and void the warranty. Do not handle or move the
whirlpool by the pump, motor, or piping system. Fittings (bath filler,
shower arm, etc.) are not provided with the bath and must be ordered
separately. Framing and enclosing materials are provided by others.
IMPORTANT: Water test unit before installation and
enclosure!
• Bath Filler*
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
© American Standard Inc. 2002
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

Advertisement

loading

Summary of Contents for American Standard Williamsburg Elite 5' Integral Apron Whirlpool 2425E-LHO

  • Page 1: Installation Instructions

    752876-100 Rev. E 2425E-LHO 2425E-RHO WHIRLPOOL INSTALLATION INSTRUCTIONS THANK YOU... for selecting an American Standard bath. Your new bath is shipped to WATER you after careful inspection. the whirlpool version is completely RETENTION FLANGE assembled with pump, motor, and system piping. All you need to finish...
  • Page 2 INSTALLATION AND FRAMING INSTRUCTIONS Locate studs as required. Ensure roughing-in dimensions are proper, plumb and square. Access to Pump/Motor may be made through the access opening in the apron panel. It is strongly recommended that an additional opening be provided for access to the drain components.
  • Page 3: Read And Follow All Instructions

    ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter.
  • Page 4 W IRE SEL EC TI O N G U I D E Mot or 50 ' Hi-Per fo r mance Rating DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight.

This manual is also suitable for:

Williamsburg elite 2425e-rho