Download Print this page
American Standard Williamsburg Elite 2425E SERIES Installation Instructions
American Standard Williamsburg Elite 2425E SERIES Installation Instructions

American Standard Williamsburg Elite 2425E SERIES Installation Instructions

5' x 32" whirlpool, high gloss acrylic shown less all fittings

Advertisement

Quick Links

WILLIAMSBURG
ELITE 5' x 32"™
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
12
(305mm)
10-1/4
(260mm)
3/4
(19mm)
FINISHED
WALL
SEE FITTING
SPECS FOR
DIMENSIONS
9
(229 mm)
32
16
(813mm)
CUTOUT IN FLOOR FOR DRAIN
(406mm)
C/L OF
3
SUPPLIES
(76mm)
C/L OF DRAIN
OPTIONAL TO
FINISHED FLOOR
LEVELING
USUALLY BETWEEN
STRINGER
65 & 78
NOT FOR
(1651 & 1981mm)
SUPPORT
C/L OF
OVERFLOW
3-1/2
(89mm)
21-1/2
(546mm)
ROUGH
FLOOR
INTEGRAL
FEET
1-1/2 O.D.TAILPIECE
GENERAL SPECIFICATIONS FOR 2425E WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
3
CUBE (FT
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
752875-100 Rev. D
2425E SERIES
WHIRLPOOL

INSTALLATION INSTRUCTIONS

60
(1524mm)
PUMP
(8) JETS
(2) AIR VALVES
C/L OF
SHOWER ARM
FINISHED
WALL
C/L OF
VALVES
C/L OF
12
SPOUT
(305mm) OPT.
2
4
(51mm)
(102mm)
19-1/2
(495mm)
1-1/2 N.P.T.M.
THREADS
2-3/4
(70mm)
4-5/8
(117mm)
60 x 32 x 21-1/2 (1524 x 813 x 546mm)
115 Lbs. (52 Kg.)
574 Lbs. (258 Kg.)
55 Gal. (208 L.)
45 Gal. (171 L.)
16-1/4 x 38-1/4 (413 x 972mm)
26-1/4 x 52-1/2 (667 x 1334mm)
15 (381mm)
43 Lbs./Sq.Ft. (208 Kgs./Sq.m)
20.8
35.3
1.6 HP, 9.7 AMPS,120V.
ON/OFF

THANK YOU...

SWITCH
HEATER
for selecting an American Standard bath. Your new
BLANK
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
PROVIDE ACCESS
connections for a whirlpool.
TO PUMP FOR
SERVICE ON ALL
INSTALLATIONS
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
List of Optional Components (not included):
• Flex-Jet Pulse Jet Kit*
• Flex-Jet Soft Jet Kit*
• 5 Foot Apron*
• E-Z-Install Heater*
List of Required Components (not included):
UNDERSIDE
• Drain*
OF DECK
IN-LINE HEATER
* see your Home Depot Retailer
REMOVABLE
BLANK
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
• Bath Filler*
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
• Drop Cloth
• 15 amp GFI
• Cement, Plaster,
© American Standard Inc. 2002
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
Stringers
Outlet
Grout

Advertisement

loading

Summary of Contents for American Standard Williamsburg Elite 2425E SERIES

  • Page 1: Installation Instructions

    Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
  • Page 2 INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls.
  • Page 3: Read And Follow All Instructions

    ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter.
  • Page 4 W IR E SE LEC TI O N G U IDE M a xi mu m d i st anc e f ro m The sizes s hown on t h is fu se bo x t o m o t or chart are recomm enda t ion s Motor 5 0'...