General Instructions; Handing The Appliance Over To The Customer; Technical Service - BaltGaz NEVALUX-5611 User Manual

Baltgaz nevalux lux instantaneous gas water heater for domestic use
Table of Contents

Advertisement

The lame of the main burner is
weak, stretched, with yellow smoky
tongues.
After a short period of operation
the appliance switches off.
Insufficient water heating (the
specified heating effect is not pro-
vided).
While the appliance is operating,
increased noise of flowing water is
noticed
The burner's flame doesn't go out
when the hot water tap is closed.
*The works are effectuated by a specialized service organization.

10. GENERAL INSTRUCTIONS

10.1. Mounting of gas appliances for domestic use must be effectuated in accordance with the project for appliance's installation
and the set of rules SP 62.13330.2011.
10.2. The appliance must be installed on fire-resistant walls (brick, concrete, with ceramic plating).
10.3. The appliance's installation and technical service must be done only by a specialized service organization. The appliance
must be connected only to the gas category that is indicated in the user's manual and the table on the appliance
10.4. The installed appliance must be obligatory registered in the gas facilities service.

11. HANDING THE APPLIANCE OVER TO THE CUSTOMER

11.1. After installing the appliance, the installer must check its operation in the rated conditions. If it's necessary the appropriate ad-
justments should be performed for achieving the values indicated in the "User's manual"
11.2. After termination of mounting and adjusting works the consumer should be instructed about the order of using the appli-
ance:
rules of water quantity regulation;
rules of gas quantity regulation;
order of switching the appliance on and off;
Appliance treatment works, effectuated by the customer.
The mark about the instruction must be made in the Certificate of the Installation and technical service. There should also be a
mark about the appliance's installation.

12. TECHNICAL SERVICE

In order to ensure long-term and failure-free operation of the appliance and to keep its operating characteristics it is necessary to
regularly make the examination, treatment and technical service.
Dust deposit on the burner's nozzles and inner
surfaces
Insufficient draught (the appliance is switched
off by the automatic control system).
The water unit membrane is damaged
The contact with the flame sensor is disrupted or
the sensor's electrode touches the burner's de-
tails or is out of the flame zone (the burner oper-
ates for 7 seconds at continuing spark discharges
and then switches off).
Appearance of soot deposit on the flame sen-
sor's electrode
Dust deposit in the burner's channels, soot de-
posit on the heat exchanger's fins or scale de-
posit in the heat exchanger's pipes.
Low gas pressure.
Water or gas unit is out of order.
Big water consumption.
Skewed gaskets in the joints of the water tract
Water overheating in the heat exchanger.
Jamming of the rod of the water or gas unit.
User's and technical staff manual
Effectuate the burner's cleaning.*
Close the hot water tap and at the next switch-
ing on(in 1-2 minutes) reduce the hot water
temperature, reducing gas consumption or in-
creasing water consumption
Replace the water unit membrane.*
Restore the contact with the flame sensor, adjust
its electrode's position.*
Effectuate cleaning of the flame sensor from
soot deposit*.
Effectuate cleaning of the burner and heat ex-
changer.*
Call the gas facilities service in order to elimi-
nate the cause of low pressure.
Repair or replace the unit that is out of order.*
Reduce water consumption.
Replace the gaskets.*
Reduce gas supply or increase water consump-
tion.
Close the gas stop valve by the appliance's inlet
and call a specialized service organization for
the appliance's repair.

Advertisement

Table of Contents
loading