To ensure long-term and failure-free-free operation of the appliance and keep its operating characteristics it is necessary to regu-
larly effectuate its examination, treatment and technical service.
To ensure fire safety it is necessary to carefully and attentively look after the burners' cleanliness, not to allow smoky flame ap-
pearance at gas combustion, which leads to soot deposit appearance on the heat exchanger. At that gaps between the heat exchanger's
fins acre covered with soot and as a result the flame casts out from the combustion chamber which can lead to fire.
The examination and treatment of the appliance are performed by the owner.
Technical service of the appliance is performed by the specialized service organization not later than 12 months from the date of
installation and then not less than once per 12 months.
ATTENTION! Works connected with technical service are not the manufacturer company's warranty liabilities and are
effectuated at the customer's cost.
4.1.

Examination

4.1.1. Every time before switching the appliance on it is necessary to:
-Make sure that there are no flammable objects next to the appliance;
-Make sure that there is no smell of gas in the premise, in case if the smell of gas is detected, call the gas facilities emergency
service.
4.1.2. After the main burner's ignition it is necessary to visually check its operation: the flame should be blue and straight with-
out any yellow smoky edges indicating the contamination of the inner channels of the burners' blades.
The burner blades' inner channels contamination causes incomplete gas combustion and it leads to the following phenomenon:
-Appearance of large amounts of carbon monoxide (sweetdamp) which can cause poising;
-Appearance of large amounts of soot and its deposit on the heat exchanger which worsens heat exchange and can cause the ap-
pliance's breakdown.
4.2.

Treatment

4.2.1. The appliance should be kept clean, for this it is necessary to regularly remove dust from the upper surface of the appli-
ance, and also to wipe the casing at first with a wet rag, then with a dry one. In case of substantial contamination, it is necessary to
wipe the casing at first with a wet rag moistened in a neutral detergent, then with a dry rag.
12.2.2. It is forbidden to use a detergent of heightened effect and containing abrasive particles, gasoline or any other organic sol-
vents to clean the surface of the casing and plastic parts.
ATTENTION! It is allowed to perform all appliance treatment operations only after the appliance is switched off and
cooled down.

RULES OF TRANSPORTATION AND STORAGE

5.
5.1. The appliance must be kept and transported in the package only in the position indicated on the handling marks.
5.2. The appliance should be kept in a closed premise which guarantees protection against atmospheric and other harmful
impacts at the air temperature from -50 С to +40 С and relative humidity not more than 98%.
5.3. In case of the appliance's storage for more than 12 months it must be subject to conservation in accordance with GOST
9.014 – 78 standard.
5.4. Apertures of the inlet and output fittings should be closed by the gauges or plugs.
5.5. Every 6 months the appliance should go under technical examination, during which the absence of wet entry and dust
contamination of unit and parts of heat exchanger are checked.
5.6. The appliances should be put in not more than 8 tiers during collection into stacks and transportation.

6. SAFETY MEASURES

6.1. Mounting of the appliance, putting it into operation and its technical service must be performed only by a specialized
service organization. The appliance's mounting should be effectuated in accordance with the project corresponding to the
requirements of the Federal and local regulatory acts, governing the installation of the gas-powered equipment.
6.2. Placing the appliance, pipelines, exhaust flues, smoke exhausters and other engineering equipment should provide safety of
their operation, ease of technical service and repair.
6.3. Before connecting the appliance it is necessary to do the following:
-Check the compliance of the settings indicated in the Acceptance certificate and in the table on the appliance with the type and
pressure of gas available at the place of the appliance's installation. In case of non-compliance it is necessary to effectuate the
appliance's rendering to the used type and pressure of gas in accordance with p.7.10 (page 16)
-To make sure that the exhaust flue is correctly mounted and air-tight;
- In order to provide the appliance's correct operation and keep the warranty, it is necessary to follow the requirements of this
manual.

7. APPLIANCE INSTALLATION

The appliance must be installed by the specialized service organization.