13
13
Accessories
A. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk! Use with solid
wood fuel or decorative gas appliance only. Gas fi re gener-
ates fumes.
•
DO NOT install unvented gas logs
•
Damper must be locked fully open when gas logs are
installed
A certifi ed gas log lighter or decorative gas log set can be
installed in this fi replace.
•
Maximum input is 150,000 BTU/hr.
•
Decorative gas appliance must be certifi ed to ANSI Z21.60
"Standard for Decorative Gas Appliances for Installation
in Vented Fireplaces".
•
Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1.
•
A gas log set must incorporate a gas shutoff.
•
Gas log set requires the damper to be locked fully open.
•
A listed automatic damper system with safety interlock may
be used in this fi replace with only compatible, listed gas log
sets. See damper system manufacturer's instructions.
•
Knockouts are provided on both sides of the fi replace for
1/2 in. (13 mm) iron pipe.
•
A locating dimple (see Figure 13.2) is located on both sides
of the fi replace in the molded brick panels for drilling a 1
in. (25 mm) diameter hole for installation of a gas line.
After the panel is installed, drill the hole for the gas line.
•
Seal panel around pipe with fi replace mortar or a high
temperature, non-combustible sealant.
B. Wood Burning Inserts
WARNING! Risk of Fire! Improper installation of wood
inserts may cause fi replace or chimney system to overheat.
If a wood burning insert is being installed in this fi replace,
Hearth & Home Technologies recommends full reline of the
chimney.
•
Cooling air openings at the top of the chimney must not
be obstructed in any manner.
•
Hearth & Home Technologies recommends securing the
reline at the top of the fl ue and using the cap certifi ed for
use with this fi replace system.
48
Heat & Glo • RUTHERFORD-36 • 4059-341 Rev D • 03/09
Firebox
Refractory
Seal with
fireplace mortar
or non-combust-
ible sealant
Gas line
Repack
insulation
knockout
4 in.
(102 mm)
Figure 13.1 Gas Line Installation
Figure 13.2 Gas Line Dimples
Outer shell
of fireplace
Maintain air clearance
to combustibles.
Combustible
materials
1 1/2 in. (38 mm)
air space around
pipe
Gas line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
Gas Line
Dimple
Gas Line
Dimple