D. Install Ceiling Firestops
CAUTION! Risk of Fire! Ceiling fi restops must be used
whenever the chimney penetrates a ceiling/fl oor.
Chase construction requires ceiling fi restops at each fl oor
or every 10 ft (3.05 m) of clear space.
The ceiling fi restop slows spread of fi re and reduces cold
air infi ltration.
Install a ceiling fi restop whenever chimney penetrates
ceiling/fl oor.
Mark and cut an opening in ceiling as shown in
Figure 8.5.
Frame the opening with the same size lumber used in the
ceiling joists.
Nail the ceiling fi restop to the bottom of the ceiling joists
when there is a room above/
Use an attic insulation shield if the ceiling is insulated. The
ceiling fi restop may then be attached above or below the
joists. Refer to Figure 8.6 and 8.7.
WARNING! Risk of Fire! DO NOT seal area between
fi restop opening and chimney pipe except where they
enter the attic or leave the warm-air envelope of the
home (use 600° F sealant).