TEMPERATURE CONTROL

HOTTER WATER INCREASES THE RISK OF SCALD INJURY.
This water heater can deliver water at temperatures which can cause scalding.
Water heating applications: It is necessary and we recommend that a temperature limiting device be fitted
between the water heating system and the hot water outlets in any ablution and public areas such as bathrooms,
ensuites or public amenities, to reduce the risk of scalding. The installing plumber may have a legal obligation to
ensure the installation of this water heater meets the delivery water temperature requirements of AS/NZS 3500.4
so that scalding water temperatures are not delivered to a bathroom, ensuite, or other ablution or public area.
THERMOSTAT ADJUSTMENT
On/Off models (Eliwell Thermostat)
The instrument has two main menus: the "Machine Status" and "Programming"menu.
ACCESSING AND USING MENUS
The instrument is programmed by menus. To access a menu, press and quickly release the "SET" key ("Machine
status menu) or press the "SET" key for over 5 seconds ("Programming" menu). To access the contents of each
folder, indicated by the relevant label, just press the "SET" key once. You can now scroll through the contents of
each folder, modify it or use its functions. If you do not use the keyboard for over 15 seconds (time-out) or if you
presence the "FNC" key once, the last value shown on the display is confirmed and you return to the previous
screen mask.
MACHINE STATUS MENU
To access the "Machine Status "menu, press and quickly release the "SET" key. The "Set" folder label appears. To
view the Setpoint value, press the "SET" key again. The Setpoint value appears on the display. To change the
Setpoint value, use the "UP" and "DOWN" keys within 15 seconds. If the parameter is LOC = y the Setpoint cannot
be changed.
PROGRAMMING MENU
To enter the "Programming" menu, press the "SET" key for more than 5 seconds. If specified, the access
PASSWORD will be requested, (parameter "PA1"), and the label of the first folder will follow. To scroll through the
other folders, use the "UP" and "DOWN" keys. To enter the folder, press "SET". The label of the first visible
parameter appears. To scroll through the other parameters, use the "UP" and "DOWN" keys. To change the
parameter, press and release "SET" then set the desired value with the "UP" and "DOWN" keys, and confirm with
the "SET" key, to move to the next parameter.