Electrical Connection

A 15 AMP, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the fireplace
will be on a dedicated circuit as other appliances on
the same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is in operation. The
unit comes standard with a 6 ft. (1828 mm) long three
wire cord, exiting the right side of the fireplace. Plan
the installation to avoid the use of an extension cord. If
an extension cord must be used, it must be a minimum
14AWG, three wire with grounding type plug and
connector and rated not less than 1875 Watts. The
extension cord shall not be more than 20 feet in
length.
A new electrical outlet can be installed inside the frame
construction, if permitted by local codes.
Electrical outlet wiring must comply with
local building codes and other applicable
regulations to reduce the risk of fire,
electrical shock and injury to persons.
Do not use this fireplace if any part of it
has been under water. Immediately call a
qualified service technician to inspect
the fireplace and replace any part of the
electrical system which has been under
water.

Hard (Direct) Wire Connection

If desired, a qualified electrician may remove the cord
connection, and wire this unit directly to the household
wiring. See Page 14.
6
Adjustable Drywall Strip
(Nailing Flange)
Screw
Drywall
Position
Depths
A
1/2" / 13 mm
B
5/8" / 16 mm
C
3/4" / 19 mm
Adjustable 1/2",
5/8", 3/4"
FP1023
Spacing
Any electrical rewiring of this appliance
must be done by a qualified electrician.
This wiring must be done in accordance
with local codes and/or in Canada with
the current CSA C22.1 Canadian
Electrical code, and for U.S.A.
installation, National Electrical Code
ANSI/NFPA Nº 70.
WARNING: This fireplace comes with a
manual circuit breaker reset beside the
On/Off switch. In case the fireplace is not
operating check the circuit breaker and
reset the button at the breaker. If the
fireplace is still not operating immedi-
ately call a qualified service technician to
inspect the fireplace.

Removal of Logs

1. Turn off power to the unit.
2. Remove front glass (See "Glass Removal" section).
3. The log bottom is shipped in place. No adjustment is
necessary.
Fig. 4 HEF33 unitized log set.

Installation of Trim Kit Assembly

INSTALLATION:
1. Peel all plastic from the Trim kit Assembly.
2. Press the Trim Kit Assembly onto the front of the
fireplace. To facilitate the installation process,
these pieces are magnetized. Align the top of the
Trim Kit Assembly with the top of the fireplace.
Fig. 5 Trim Kit Assembly installation.