Electrical Wiring Diagram Without Integral Remote Control; Ceramic Refractory Installation - pyromaster HEF33 Homeowner's Installation & Operating Manual

Pyromaster
Table of Contents

Advertisement

Pyromaster Electric Fireplace HEF33

Electrical Wiring Diagram without Integral Remote Control

10
11
Component Identification:
1. Motor, Variable Speed 12VDC
2. Switch ON/OFF
3. Thermostat
4. Fan/Heater
5. Light Socket with Wiring Assem.
6. Light Bulb, 60W
7. Breaker Circuit Manual Reset
8. Power cord 16/3 HPN with Terminal
1. Remove glass door assembly or bay window
assembly.
2. Remove two screws found on the top of firebox
behind firebox deflector. Attach adjustable brackets
packed with refractory.
3. Slide refractory side panels on the firebox bottom
and behind side bracket and adjust, fitting the
ceramic tight to the side of firebox (Fig. 8). Tighten
screws.
4. Reinstall glass door assembly or bay window
assembly.
10
11
4 RED
5 WHITE
4
FLAME
MOTOR
13
RED
+
SPEED
CONTROL
WHITE
-
14
5 WHITE
4 RED
T'
S
T
A
3
T
9. Bushing Straight-Thru Strain Relief
10. Cable Tie Nylon, 6" x 1
11. Bushing Snap 0.875"-0.625"
12. CFM-Majestic Wire Required
13. Circuit Board Flame Speed Control
14. Potentiometer Assem.

Ceramic Refractory Installation

FAN
MOTOR
4
HEATER
ELEMENT
WHITE
BLACK
1 BLACK
BREAKER
CIRCUIT
S
O
W
N/
I
O
T
F
C
F
H
2
Side
Tab
Side
Panel
Fig. 8 Ceramic refractory installation.
6
5
8
7
9
Wiring Color Code:
1
/
" Black
WH =
8
BL =
RE =
White
Black
Red
Side
Tab
Side
Panel
FP1207
10005721

Hide quick links:

Advertisement

Table of Contents
loading