Heatilator CD4236IR-C Owner's Manual page 30

Natural gas
Hide thumbs Also See for Heatilator CD4236IR-C:
Table of Contents

Advertisement

Top Vent - Vertical Termination (continued)
3. Match the amount of vertical you have in the system
with the chart to fi nd the appropriate position to set the
Flue Restrictor (see Figure 7.10).
TOP VENT
Vertical
NG
4 ft.
1-1
Restrictor
8 ft.
2-2
15 ft.
3-3
20 ft.
3-4
25 ft.
3-4
30 ft.
4-4
35 ft.
4-4
40 ft.
4-4
50 ft.+
4-4
Figure 7.10
Note: If the DVP-2SL or DVP-SLP24 adapter is used with
SLP pipe, you MUST subtract one number from the table
above.
Example: Top vent 40 ft vertical with DVP pipe = 4-4
Top vent 40 ft vertical with SLP pipe = 3-3
Two Elbows
Figure 7.12
30
REAR VENT
LP
NG
LP
No
No
No
Restrictor
Restrictor
No
1-2
1-1
Restrictor
3-2
2-2
1-2
3-3
3-3
2-3
3-3
3-3
2-3
3-4
3-4
3-3
3-4
3-4
3-3
4-4
4-4
3-4
4-4
4-4
4-4
V
2
H
1
Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev. G • 8/10
4. Center the Flue Restrictor on vent and secure in place
by using two self-tapping screws (see Figure 7.8 and
Figure 7.11).
5. Reinstall the Exhaust Shield.
Figure 7.11
V
1
Elbow only
6 in.
152 mm
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
V
+ V
+ H
1
2
1
*No specifi c restrictions on this value EXCEPT
V
+ V
+ H
cannot exceed 60 ft (15.2 m)
1
2
1
V
1
1
2
3
4 5
SETTING
1
2
3
4 5
H
Maximum
V
V
+ V
1
2
1
2 ft.
610 mm
*
*
6 ft.
1.8 m
*
*
11 ft.
3.4 m
*
*
16 ft.
4.9 m
*
*
20 ft.
6.1 m
*
*
= 60 ft. (18.3 m) Maximum