INSTALLATION
GAS HOOK-UP
NATURAL GAS HOOK-UP (continued)
To hook-up the fittings supplied with the side burner, assemble as shown in Fig.04. Use joint compound on
male threads only.
Do not use joint compound on the flare end of the 1/2" NPT
to 3/8" flare adapter. Ensure that the regulator arrow points
in the direction of gas flow-towards the unit, away from the
supply.
Do not forget to place the installer-supplied gas valve in an
accessible location.
LP GAS HOOK-UP
CONNECTION: 1/2" NPT male with 3/8" flare adapter
(included). Use 90º elbow 1/2" NPT with 3/8" flare
(P/N 212394) for side mount models only when installing on
the cart. Use sealer on 1/2" NPT threads only.
OPERATING PRESSURE: 10.0" W.C. side burner uses the LP
regulator from adjoining grill.
SUPPLY PRESSURE: 11" to 14" W.C.
Apply joint compound to the threaded end of the side burner gas
inlet and tighten the adapter to the pipe. Assemble the 24" and 30" hoses to the 3/8" flare tee, as shown in
Fig.05. Tighten the regulator hose to the remaining fitting of the 3/8" flare tee.
LP TANK REQUIREMENTS
A dented or rusty LP gas cylinder may be hazardous and
I
should be checked by your LP supplier. Never use a cylinder
with a damaged valve.
The LP gas cylinder must be constructed and marked in
I
accordance with the specifications for LP gas cylinders of the
U.S. Department of Transportation (DOT ) and designed for
use with a Type 1 system only.
Do not change the regulator/hose assembly from that
I
supplied with the unit or attempt to use a Type 1 equipped
regulator/hose assembly with a standard 510 POL tank/valve
assembly. The cylinder must be provided with a shut-off
valve terminating in an LP gas supply cylinder valve outlet
specified, as applicable, for connection Type 1.
If the appliance is stored indoors, the cylinder must be
I
disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well ventilated area
I
out of the reach of children.
Gas cylinder supply must be turned off when not in use.
I
Bottom of
131 &132 Burner
Open Top
Manifold
1/2" Coupling
1/2" NPT x 2.0"
Nipple
Regulator
1/2" NPT x 2.0"
Nipple
1/2" NPT to 3/8"
Flare Adapter
To Gas Supply
FIG. 04 Natural Gas
FIG. 05 LP Gas