G SERIES MODELS - ERROR MESSAGES (CONT.)
2.)
"SYSTEM OVER TEMPERATURE" ALARM
• A system over temperature alarm will activate as a safety when the unit has overheated to protect the
compressor.
• The system automatically goes to "OFF" status where the compressor's operations is stopped, while
augers will keep working to avoid forming ice blocks.
• When this occurs an "Err" message will appear on the touch pad LED readout accompanied by a continu-
ous buzzer sound to alert the operator of this condition.
• When this alarm activates, turn off all switches. Then determine the condition. (See "Filter Cleaning" Alarm
Section for Conditions and Corrective Actions)
Operating Panel Description-MG Series Traditional
Rocker Switch Model
1.)
Turn ON the main power switch
2.)
Description of the buttons (see figure cc):
Each bowl is controlled by three switches which have the following functions:
(E) activates the mixing parts/spiral auger
(F) activates the freezing of the product
(G) activates the refrigeration of the product (night/defrost setting)
To obtain a slush:
Select the
(E) switch to activate the mixing parts/spiral auger and
select the
(F) switch to activate the freeze mode.
Note: There is a 4 minute delay before the compressor will start.
To obtain cold (night/defrost) drinks:
Select the
(E) switch to activate the mixing parts/spiral auger and
select the
(G) switch to activate the refrigeration mode.
Stand-by mode setting:
Select the
(E) switch to activate the mixing parts/spiral auger and the
mode to keep the product(s) in bowl(s) overnight.
Defrost Timer Operating Instructions
1.) SETTING CURRENT TIME - Rotate the program disc, in the direction of
the arrows, to align the correct time of day with the time of day mark.
Figure H shows the timesetting of 7:00.
2.) SETTING DEFROST MODE - Set the defrost period by pushing the switch
actuator toward the outer edge of the program disc. Freeze time is set by pushing the
switch actuators toward the center of the time switch. Figure N shows a defrost time
from 11:00 to 6:15. The light and dark shaded areas of the program disc indicate day and night respectively.
Each actuator is equivalent to 15 minutes.
3)
All switches (power, auger, refrigeration and freeze) must be "on" for defrost timer to properly function.
NOTE: The timer is battery backed. Do not remove power from the unit for greater than 2 weeks as doing so will
result in failure of the battery back-up feature. The battery is nickel cadmium and will last from 6 to 8 years if
properly charged. The battery is not replaceable upon failure.