Maintenance; Cleaning & Sanitizing - Grindmaster Crathco G235-2B Operation And Instruction Manual

Visual granita machine
Hide thumbs Also See for Crathco G235-2B:
Table of Contents

Advertisement

Cleaning and Sanitizing Procedures (con't)
16.)
Plug the unit back into appropriate power supply.
17.)
After the cleaning and reassembly of the mixing parts and bowl as per above instructions, fill the bowl with a
mix of water and an approved cleaning solution (example kay5), according to the measures specified.
18.)
Start the mixing part of the machine for about 10 minutes to sanitize all parts. Follow the cleaning solution
specifications.
19.)
Drain the cleaning solution as follows:
• Unscrew the two knobs (F) see fig. U);
• then lower the bowl to drain out any remaining product through the dispensing valve (C)
(as shown in fig. U).
20.)
Screw again the knobs (F) to fix the bowls.
21.)
With a clean cloth wash the underside of the lamp cover with warm water and a mild detergent. Allow this
part to air dry and then wipe it with a clean cloth which has been dipped in the sanitizing mixture.
Prepare a minimum of 4 gallons (15 liters) of sanitizing solution (Stera Green
Label or equivalent) following the manufacturer's instructions.
Note: Add 4 ounces of Stera Sheen to 4 gallons (15 liters) of 120° Fahrenheit
(50° Centigrade) water to achieve a concentrate of 100 parts per million.
Warning:
Lamp cover must be unplugged. Electric shock
!
could occur if cover or power cord come in contact with
solution.

Maintenance

Warning:
!
Disconnect the unit from its power supply prior to
performing any maintenance procedures. Failure to do so could result in
electric shock, injury from hazardous moving parts or serious burns from
hot surfaces.
Removing and cleaning the filter (Weekly)
This should be done weekly or more often if necessary.
In order to guarantee an efficient refrigerating system, it is essential that the
filter be properly cleaned, according to the following procedures:
1) Unplug the machine.
2) Unscrew the knob (K) in order to remove back panel (see fig. FF).
3) Remove the filter (W) held inside the back panel (X) and clean
it properly using water or vacuum (see fig. GG).
4) Place the cleaned filter back inside back panel and reinstall the back
panel on the machine by screwing in the knob (K).
Attention:
!
Failure to maintain a clean filter and condenser will
cause damage to the unit not covered by warranty.
G & MG Series Granita Machine
(Figure EE)
(Figure FF)
(Figure GG)
Page 11

Advertisement

Table of Contents
loading

Table of Contents