Figure 3-15. Create Temp Selection Screen - ADTRAN TSU 120 User Manual

Part number 1200129l1
Hide thumbs Also See for TSU 120:
Table of Contents

Advertisement

61200.129L1-1
CREATE TEMP
This creates a map by defining a port or Idle for all
DS0s. Any or all of the DS0s can also be designated
for Passthru if a secondary interface capable of
Passthru is present. When 2)CREATE TEMP is
selected, all DS0s are set to Idle, and those in use are
set to the proper port.
A sample selection follows:
DS0: 01 to 24
PASSTHRU: Y for Yes
N for No
PORT: IDLE, TST, 0.1 NX56/64(+ other Ports)
TST is used to designate which DS0s are used for QRSS
testing when activated under the 4)TEST Menu. When not
used for testing, the TST designation is identical to IDLE.
With the cursor on 2)CREATE TEMP, press Enter. The
unit displays the selection screen with the cursor
positioned on the first selection DS0 number. See
Figure 3-15.
Select DS0 Number
Use either the scroll method or numbers to enter the
DS0 number (do not mix the use of the keys). Pressing
Enter completes the selection and moves the cursor to
the next field, Passthru. Scroll to change, Y for Yes or
N for No. Press Enter to complete the selection and
move the cursor to the next field, PORT.
TSU 120 User Manual
Chapter 3. Operation
Select Port
CREATE TEMP Selection Screen
Passthru
Yes or No
Figure 3-15
6 9

Advertisement

Table of Contents
loading

Table of Contents