GHP Group TT15CL User's Manual And Operating Instructions

GHP Group TT15CL User's Manual And Operating Instructions

Propane tank top construction heater

Advertisement

USER'S MANUAL AND OPERATING INSTRUCTIONS
MODELS:
C
ANS Z83.7b-2009 CSA 2.14b-2009
GHP Group, Inc.
8280 austin ave.
GHP
Morton grove, il 60053-3207
8280 Austin Avenue
M o r t o n G rove , I L .
6 0 0 5 3 - 3 2 0 7
Tel: ( 847 ) 324 - 5900
Fax: ( 847 ) 324 - 5901
Toll Free (877) GHP Group
( 8 7 7 ) 4 4 7 - 4 7 6 8
www.ghpgroupinc.com
GENERAL HAZARD WARNING
Failure To CoMply wiTh The preCauTionS and inSTruCTionS provided wiTh
ThiS heaTer, Can reSulT in deaTh, SeriouS Bodily injury and properTy loSS,
or daMage FroM The hazardS oF Fire, exploSion, Burn. aSphyxiaTion, CarBon
Monoxide poiSoning, and/or eleCTriCal ShoCk.
only perSonS who Can underSTand and Follow The inSTruCTionS Should
uSe or ServiCe ThiS heaTer.
iF you need aSSiSTanCe or heaTer inForMaTion SuCh aS an inSTruCTion
Manual, laBelS, eTCeTera, ConTaCT The ManuFaCTurer.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday
50-10-106
PROPANE TANK TOP
CONSTRUCTION HEATER
TT15CL, TT30CL,
TT15CDGP, TT30CDGP,
TT15CDGD, TT15CPDGD, TT30CDGD, TT30CPDGD
US
CONSUMER: retain this manual for future reference.
or email us at customerservice@ghpgroupinc.com
www.ghpgroupinc.com
Printed in China
Rev. 0/10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TT15CL and is the answer not in the manual?

Questions and answers

Summary of Contents for GHP Group TT15CL

  • Page 1 6 0 0 5 3 - 3 2 0 7 Tel: ( 847 ) 324 - 5900 Fax: ( 847 ) 324 - 5901 Toll Free (877) GHP Group ( 8 7 7 ) 4 4 7 - 4 7 6 8 www.ghpgroupinc.com...
  • Page 2: Table Of Contents

    6 0 0 5 3 - 3 2 0 7 Tel: ( 847 ) 324 - 5900 Fax: ( 847 ) 324 - 5901 Toll Free (877) GHP Group ( 8 7 7 ) 4 4 7 - 4 7 6 8 www.ghpgroupinc.com...
  • Page 3: Specifications

    SPECIFICATIONS WEIGHT MODEL BTU OUTPUT (high) IGNITION TYPE OPERATING TIME PRODUCT PACKAGED (20 lb. cylinder) TT15CL 15,000 Match 28 Hrs. (high) 2.52 lbs / 1.14 kg 3.48 lbs / 1.58 kg TT15CDGP 15,000 Match 28 Hrs. (high) 2.52 lbs / 1.14 kg 3.48 lbs / 1.58 kg...
  • Page 4: Product Features

    PROPANE TANK TOP HEATER GENERAL SAFETY INSTRUCTIONS accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater. IMPORTANT SAFETY INFORMATION •...
  • Page 5: Heater Assembly

    PROPANE TANK TOP HEATER HEATER ASSEMBLY Tools Required: phillips head screwdriver dual burner models only The tank collar bracket must be assembled before the heaters can be attached to the propane tank. 1. align bolt holes in tank collar bracket and piezo bracket with bolt holes in center plate on manifold. 2.
  • Page 6: Wiring Diagram

    PROPANE TANK TOP HEATER WIRING DIAGRAM Spark plug earth yellow TherMoCouple black M,p,u SaFeTy valve...
  • Page 7: Refilling The Propane Gas Tank

    PROPANE TANK TOP HEATER PROPANE SUPPLY This heater requires a 20 lb propane cylinder for operation. (not included). The propane (LP) gas tank must also be equipped with the following: • a collar to protect the propane gas valve. • a shutoff valve terminating a propane gas cylinder valve outlet as specified in the american national Standard for Compressed gas Cylinder valve outlet and inlet Connections.
  • Page 8 PROPANE TANK TOP HEATER CONNECTING HEATER TO PROPANE TANK read and understand all safety information before connecting heater to propane tank. 1. (applies to dual burner models only). place heater onto tank with tank collar bracket over tank collar (Fig. 1) Mounting bolt knob should be positioned to the outside of tank collar.
  • Page 9 PROPANE TANK TOP HEATER CONNECTING HEATER TO PROPANE TANK FIGURE 2 Spark plug TT30 SERIES piezo (noTe: some models only) Tip over Switch inlet Connector propane Tank valve Mounting Bolt knob heat regulator knob Fuel Connecting Bolt ( handle) FIGURE 3 Spark plug TT15 SERIES ignition hole...
  • Page 10: Checking For Leaks

    PROPANE TANK TOP HEATER CHECKING FOR LEAKS Check all gas connections with a 50/50 soap and water solution to be sure they are tight and leak proof. The formation of bubbles indicate a gas leak. Correct all leaks before using the heater. •...
  • Page 11 PROPANE TANK TOP HEATER LIGHTING INSTRUCTIONS WHEN USING MATCH (CONTINUED) FIGURE 4 1. open Cylinder valve by turning counterclockwise Burner Front 2. Turn heater regulator knob counterclockwise to the Spark plug “high” position. (Fig. 4) WARNING: Stand to the side of unit while ignition hole lighting.
  • Page 12 PROPANE TANK TOP HEATER TURNING OFF THE HEATER 1. Tightly close propane tank valve by turning clockwise 2. Turn the heater regulator knob to the oFF position. wait at least 30 minutes for the heater to cool before handling heater. 3.
  • Page 13 PROPANE TANK TOP HEATER LIGHTING INSTRUCTIONS FOR PIEZO IGNITION MODELS (CONTINUED) 1. Stop! read all safety information first. 2. open cylinder valve by turning counterclockwise WARNING: Stand to the side of unit while lighting. Do not stand or have any part of your body over or in front of heater while lighting.
  • Page 14: Maintenance

    PROPANE TANK TOP HEATER LIGHTING UNDER WIND CONDITIONS when using this heater outdoors on a windy day, it will be necessary to use a match or long stem butane lighter to ignite the burner. it may be difficult to keep the match lit long enough under windy conditions. Follow the “lighting instructions when using a Match”...
  • Page 15: Troubleshooting

    PROPANE TANK TOP HEATER TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1. Unit will not light. 1. Valve on propane cylinder not open. 1. Open cylinder valve by turning counterclockwise. 2. Propane cylinder empty 2. Have cylinder refilled. 3. Regulator not in "High" position 3.
  • Page 16 PROPANE TANK TOP HEATER REPLACEMENT PARTS ILLUSTRATION TT15 SERIES TT30 SERIES...
  • Page 17 ThiS page inTenTionally leFT Blank.
  • Page 18: Warranty

    This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase.
  • Page 19: Warranty Registration

    6 0 0 5 3 - 3 2 0 7 Tel: ( 847 ) 324 - 5900 Fax: ( 847 ) 324 - 5901 SAVE THIS CARD! Toll Free (877) GHP Group ( 8 7 7 ) 4 4 7 - 4 7 6 8 www.ghpgroupinc.com Place...

Table of Contents