Crankcase Components
B
A
A
Oil Seal
E
Regulating Pin
I
Nipple
M
Piston Pin Retainer
Q
Piston Rings
Remove Closure Plate
1. Remove screws securing closure plate to crankcase.
If a thick washer is installed under screw head in #10
location, and/or one silver (ground) screw is used,
(normally No. 4 or 6 position), note these special
assembly details for proper reassembly later.
2. Locate three splitting tabs, which are cast into
perimeter of closure plate. Insert drive end of a 1/2"
breaker bar between top splitting tab and crankcase.
Hold handle horizontal and pull it toward you to
break RTV seal. If necessary, pry at bottom splitting
tabs also. Do not pry on sealing surfaces, as this
could cause leaks. Carefully pull closure plate from
crankcase.
66 690 07 Rev. --
F
D E
C
H
G
J
I
B
Governor Gear Shaft
F
Cam
J
Oil Filter
N
Piston Pin
KohlerEngines.com
Disassembly/Inspection and Service
L
K
M
Locking Tab Thrust
C
Washer
G
Gerotor
K
Crankshaft
O
Connecting Rod
Inspection
Inspect oil seal in closure plate and remove it if it is worn
or damaged.
Inspect main bearing surface for wear or damage.
Replace closure plate assembly if required.
A