EFI System
Following chart lists fault codes, what they correspond to, and what visual indications will be. Following chart is a
list of individual codes with an explanation of what triggers them, what symptoms might be expected, and probable
causes.
Diagnostic Code Summary
Blink
OBD2
Code
P-Code
No RPM Signal
21
P0335
Loss of Synchronization
22
P0122
TPS - Open or Short Circuit to Ground
22
P0123
TPS - Short Circuit to Battery
23
P0601
Defective ECU
24
-
Engine Speed Sensor
31
P0174
System too Lean
31
P0132
O2 Sensor Circuit: Shorted to Battery
32
P0134
O2 Sensor Circuit: No Activity Detected
33
P0175
System too Rich
33
P0020
O2 Sensor Control at Upper Limit
34
P0171
Maximum Adaption Limit Reached
34
P0172
Minimum Adaption Limit Reached
42
P0117
Temperature Sensor Circuit: Shorted to Ground
42
P0118
Temperature Sensor Circuit: Open Circuit or Short to Battery
43
P1670
Failure Completing Autolearn - TPS Offset below minimum allowable limit
44
P1671
Failure Completing Autolearn - TPS Offset above maximum allowable limit
51
P1260
Injector 1 - Open Circuit
51
P0261
Injector 1 - Short Circuit to Ground
51
P0262
Injector 1 - Short Circuit to Battery
52
P1263
Injector 2 - Open Circuit
52
P0264
Injector 2 - Short Circuit to Ground
52
P0265
Injector 2 - Short Circuit to Battery
54
P0655
High Temperature Warning Lamp Circuit Open
54
P1657
High Temperature Warning Lamp Circuit Shortened to Ground
54
P1658
High Temperature Warning Lamp Circuit Shorted to Voltage
55
P1651
MIL Lamp - Open Circuit
55
P1652
MIL Lamp - Short Circuit to Ground
55
P1653
MIL Lamp - Short Circuit to Battery
56
P1231
Pump Relay - Open Circuit
56
P1232
Pump Relay - Short Circuit to Ground
56
P1233
Pump Relay - Short Circuit to Battery
58
P1480
Cooling Fan Driver Circuit Open
58
P1481
Cooling Fan Driver Circuit Shorten to Ground
58
P1482
Cooling Fan Driver Circuit Shorten to Voltage
61
End of Code Transmission
NOTE: 1. O2 Sensor Short to Battery diagnostic detection is disabled with SAS fuel-cutoff calibrated out.
2. System too Lean used to be O2 Sensor - Short to Ground (P0131).
3. System too Rich used to be O2 Sensor Control at Lower Limit (P0019).
4. Will not blink out.
MIL Lamp is always switched OFF when failure is SPORADIC.
36
Condition or Failure Description
KohlerEngines.com
MIL
Note
Illuminated
Y
Y
Y
Y
Y
Y
4
Y
2
Y
1
Y
Y
3
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
4
N
4
N
4
N
Y
Y
Y
Y
Y
N
N
N
N