7. Reinstall oil fill cap/dipstick and tighten securely.
8. Start engine; check for oil leaks. Stop engine; correct
leaks. Recheck oil level.
9. Dispose of used oil and filter in accordance with
local ordinances.
OIL COOLER (if equipped)
1. Clean fins with a brush or compressed air.
2. Remove screws securing oil cooler and tilt to clean
back side.
3. Reinstall oil cooler and torque to 2.2 N·m (20 in. lb.).
OIL SENTRY
(if equipped)
This switch is designed to prevent engine from starting
in a low oil or no oil condition. Oil Sentry
down a running engine before damage occurs. In some
applications this switch may activate a warning signal.
Read your equipment manuals for more information.
Oil Sentry
pressure switch is installed in breather cover.
On engines not equipped with Oil Sentry
hole is sealed with a 1/8-27 N.P.T.F. pipe plug.
Installation
1. Apply pipe sealant with Teflon
Thread Sealant or equivalent) to threads of switch.
2. Install switch into tapped hole in breather cover.
3. Torque switch to 4.5 N·m (40 in. lb.).
24 690 02 Rev. D
may not shut
installation
(Loctite
PST
592™
®
®
®
KohlerEngines.com
Testing
Compressed air, a pressure regulator, pressure gauge,
and a continuity tester are required to test switch.
ECV Models:
Normally Closed Switch
1. Connect continuity tester across blade terminal and
metal case of switch. With 0 psi pressure applied to
switch, tester should indicate continuity (switch
closed).
2. Gradually increase pressure to switch. As pressure
increases through range of 2.0/5.0 psi, tester should
indicate a change to no continuity (switch open).
Switch should remain open as pressure is increased
to 90 psi maximum.
3. Gradually decrease pressure through range of
2.0/5.0 psi. Tester should indicate a change to
continuity (switch closed) down to 0 psi.
4. Replace switch if it does not operate as specified.
Normally Open Switch
1. Connect continuity tester across blade terminal and
metal case of switch. With 0 psi pressure applied to
switch, tester should indicate no continuity (switch
open).
2. Gradually increase pressure to switch. As pressure
increases through range of 2.0/5.0 psi, tester should
indicate a change to continuity (switch closed).
Switch should remain closed as pressure is
increased to 90 psi maximum.
3. Gradually decrease pressure through range of
2.0/5.0 psi. Tester should indicate a change to no
continuity (switch open) down to 0 psi.
CV Models:
Pressure Switch
12 099 04
24 099 03
25 099 27
28 099 01
48 099 07
52 099 08
52 099 09
Lubrication System
PSI
2-6
2-5
2-5
2-6
12-16
7-11
7-11