Setup - Graco 220-240 Instructions And Parts List

Pressure roller system 17.5 bar (250 psi) maximum working pressure
Table of Contents

Advertisement

PRIMING TUBE
INLET VALVE
ON/OFF
SWITCH
POWER SUPPLY CORD
Add plug according to
local code
SPRING GUARD
MUST BE AT
THIS END
USE TWO
WRENCHES
TO TIGHTEN
ROLLER VALVE
TRIGGER
USE TWO
WRENCHES
TO TIGHTEN
Fig 2
CAUTION
To avoid premature wear of the pressure switch,
never use more than 7.6 m (25 ft) of 1/4 in. ID outlet
hose. When longer outlet hose is needed, use 3/8
in. ID hose at a maximum of 30 m (100 ft) long. Nev-
er use 1/4 in. ID and 3/8 in. ID hose together.
See ACCESSORIES, page 17, for ordering optional
hoses.
WARNING
Never remove the grounding pin of the power sup-
ply cord plug. Be sure the outlet is properly
grounded. In the event of an electrical short circuit,
grounding reduces the risk of an electric shock by
providing an escape wire for the electric current.
Inspect the power supply cord and extension cord
before each use. Be sure they are in good condition
and have undamaged three-pin plugs. Replace
immediately if either cord is worn or damaged.
307–760
SUCTION TUBE
MOTOR
ROLLER FRAME
Apply PTFE tape
to male threads

SETUP

HAND TIGHTEN ONLY
to avoid cracking roller cover
1. Assemble the system as shown in Fig 2, following the
notes on the drawing.
2. Prepare the paint according to the manufacturer's
recommendations. Remove any skin from the top of
the paint. Strain the paint. Thin the paint as needed.
3. Be sure the electrical service is properly rated for
your sprayer and that the outlet you use is properly
grounded. Install an appropriate plug on the power
supply cord, according to your local electrical code.
Do not use an adapter. All extension cords must have
three wires. Use the chart below for selecting the ap-
propriate wire gauge for the extension cord.
Cord Length
meters
1 – 30
30 – 61
61 – 92
4. Loosen the locknut on the telescoping extension and
adjust the extension to the desired length. Firmly
tighten the locknut.
HAND TIGHTEN NUT
TIGHTEN SNUGLY WITH
LIGHT WRENCH
PRIMING VALVE
PAINT STRAINER
7.6 M (25 FT) HOSE
460 TO 920 MM (18 TO 36 IN.)
TELESCOPING EXTENSION
LOCKNUT
HAND TIGHTEN ONLY
12 MM (1/2 IN.) NAP
ROLLER COVER
Extension Cord Chart
Extension Cord
Cross Sectional Area
feet
1 – 100
0.75 mm
100 – 200
1.0 mm
200 – 300
1.5 mm
2
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

221-076307760Series ePt2000

Table of Contents

Save PDF