American Standard Rondo 7242.XXXW Series Installation Instructions
American Standard Rondo 7242.XXXW Series Installation Instructions

American Standard Rondo 7242.XXXW Series Installation Instructions

High gloss acrylic shown less all fittings whirlpool

Advertisement

Quick Links

RONDO™
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
RECOMMENDED FITTING
165mm
LOCATION 64 X 279mm
(6-1/2)
(2-1/2 X 11)
267mm
(10-1/2)
PUMP
1067mm
(42)
ON/OFF
SWITCH
PROVIDE ACCESS
TO PUMP FOR SERVICE
ON ALL INSTALLATIONS
C/L OF
OVERFLOW
95mm
(3-3/4)
83mm
(3-1/4)
38mm
(1-1/2)

GENERAL SPECIFICATIONS FOR 7242 WHIRLPOOL

71-1/2 x 42 x 21-1/2 In (1816 x 1067 x 546mm)
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
751709-100 REV. L
7242.XXXW
SERIES WHIRLPOOL

INSTALLATION INSTRUCTIONS

1816mm
(71-1/2)
908mm
(35-3/4)
76mm
C/L OF DRAIN
(3)
229 X 305mm
(9 X 12)
CUTOUT
OUTLINE OF
CUTOUT
LEVELING STRINGER
SAFE-T-HEATER
NOT FOR SUPPORT
REMOVABLE BLANK
495mm
(19-1/2)
546mm
(21-1/2)
ROUGH
FLOOR
38 mm (1-1/2)
INTEGRAL
TAILPIECE
FEET
94 Lbs.(43 Kg.)
818 Lbs.(371 Kg.)
87 Gal. (330 L)
67 Gal. (254 L)
45 x 25 In. (1143 x 635mm)
60 x 30 In. (1524 x 762mm)
14-7/8 In (378mm.)
39 Lbs./Sq.Ft. (191 Kgs./Sq.m)
2.1 HP, 14.4 AMPS,120.

THANK YOU...

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.

List of Optional Components (not included):

• Safe-T-Heater 9075.120*
51mm
(2)

List of Required Components (not included):

• Drain 1583.470*
* see your Home Depot Retailer

List of Required Tools and Supplies:

Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
30.3
• Personal Safety
58.7
Equipment
• Caulking Gun
• Bath Filler*
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
• Drop Cloth
• 20 amp GFI
• Cement, Plaster,
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
Stringers
Outlet
Grout

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rondo 7242.XXXW Series and is the answer not in the manual?

Questions and answers

Summary of Contents for American Standard Rondo 7242.XXXW Series

  • Page 1: Installation Instructions

    Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
  • Page 2 INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls.
  • Page 3: Read And Follow All Instructions

    ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter.
  • Page 4 W IR E SE LECTIO N G U I DE M a ximu m d ist an ce from T he s izes sh own on th i s f us e b o x t o mo t o r chart are recom men da ti on s Moto r 50 '...

Table of Contents