ON/OFF/REMOTE Switch
is located on the wire channel. A wire harness is attached to the
push-ons attach to the ON/OFF/REMOTE switch. At the opposite
ons attach to the gas valve. An additional green wire and the red
thermostat accessory, or, to one of the other accessories that can
Operation of ON/OFF/REMOTE Switch with no Accessories
the PILOT position to the ON position. Turn the ON/OFF/REMOTE
switch from the OFF position to the ON position. The additional green
Operation of ON/OFF/REMOTE Switch with Accessories
750 Millivolt Wall Thermostat
REMOTE switch wire harness to the wall thermostat. Turn the ON/
OFF/REMOTE switch on the wire channel to the REMOTE position.
Set the wall thermostat to the desired temperature.
It is important to use wire of a gauge proper for the length of the
wire:
RECOMMENDED WIRE GAUGES
Maximum
Length
Wall Switch, FWS-1
OFF/REMOTE switch wire harness to the wall switch. Turn the ON/
OFF/REMOTE switch on the wire channel to the REMOTE position.
TRW, and FRBTC
OFF/REMOTE switch wire harness to the remote receiver that is a
component in the FRBC and FRBTC. Turn the ON/OFF/REMOTE
switch on the wire channel to the REMOTE position. Follow instruc-
tions in the FRBC and FRBTC to complete installation.
NOTICE:
is desired, turn the ON/OFF/REMOTE switch on wire channel from
the REMOTE position to the ON position.
Electric (120 volt) Operated Remote Control, FREC
OFF/REMOTE switch wire harness to the wires on remote receiver
that is a component in the FREC. Turn the ON/OFF/REMOTE switch
on the wire channel to the REMOTE position. Follow instructions in
the FREC to complete installation.
NOTICE: If electric (120 volt) fails in FREC, and immediate heat is
desired, turn the ON/OFF/REMOTE switch on wire channel from
the REMOTE position to the ON position.
Page 18

MILLIVOLT WIRING

REMOTE switch which
Wire
Gauge
Wiring of ON/OFF/REMOTE Switch with 750 Millivolt Wall
REMOTE switch wire harness to the 750 millivolt wall thermostat
AND to the remote receiver that is a component in the FRBC, FREC
OR to the FWS, wall switch.
1. Connect (1) wire from the 750 millivolt wall thermostat and (1)
wire from appropriate accessory to the GREEN, stripped and
2. Connect (1) wire from the 750 millivolt wall thermostat and (1)
wire from the ON/OFF/REMOTE wire harness.
NOTICE: When the appliance is in the MANUAL mode and the
FREC, and immediate heat is desired, turn the ON/OFF/REMOTE
switch on wire channel from the REMOTE position to the ON
position.
Manual Operation
1. Turn ON/OFF/REMOTE switch on wire channel to REMOTE
position.
2. Turn wall thermostat OFF.
3. Turn accessory, FRBC, FREC, FRBTP, TRW or FWS, ON.
Appliance is now in the manual mode. You must turn the appliance
ON or OFF with appropriate accessory.
Wall Thermostat Operation
1. Turn the ON/OFF/REMOTE switch on wire channel to REMOTE
position.
2. Turn accessory, FRBC, FREC or FWS, OFF.
3. Turn wall thermostat ON and set appropriate temperature. Wall
thermostat will cycle the appliance ON and OFF.
Installation of Remote Receiver
(Figure 18)
1. Attach, from left to right, the slide-on cover plate onto the remote
receiver. ON
the slide-on cover plate.
3. Attach Velcro loop on the left side of the valve cover support.
cover support.
cover support.
Refer to remote control installation and operating instructions
for more details on remote control.
REMOTE
RECEIVER
OFF
TOP on the
ATTACH VELCRO TO
VALVE COVER BRACKET
Figure 18
29560-0-0312