Calibration
In order to get correct readings on your instruments, the transducer has to be
calibrated. There are three things that has to be done:
1.
Enter the calibration values from the supplied calibration certificate into the
codes C56 to C62. (C55-C62 in Wind Data)
2.
Enter the misalignment of the transducer in calibration code C55. (C54 in Wind
Data)
3.
Make sure the calibration for wind speed in C54 is set to 1.70 (C53 in Wind
Data)
For information of how to enter the calibration values, se the instrument manual.
6

Specifications

Transducer cable
Power suppIy
Power consumption
Current consumption:
Wind speed range
Angle Accuracy
Speed Accuracy
Temperature range
Weight
6.1
Dimensions:
25 m
12V DC (10-16V)
0,24 W
20mA @12V
0.9-90 knots, 0.5-50 m/s
Better than ± 2°
± 5%
Operating -5ºC to +70ºC
Storage -20ºC to +80ºC
260 g.
6
TWIN FIN