TWIN FIN
4
Electric installation
4.1
Connections to the NX2 Server
If you already have a Nexus Network i.e. a Server, it is more practical to connect the
transducer to the Server due to the single instrument cable installation. Note, set C71
in Wind Data instrument to OFF (see Wind Data Manual)
Server
4.2
Connections to a Wind Data instrument
The power cable is connected via a 3A fuse from the battery or at the boats fuse panel
and direct to the instrument or Server. One red and one black power wire is included.
Note, set the Wind Data instrument to C71 On (see Wind Data Manual)
Always connect a 3 AMP fuse between Power supply and instrument.
Screen
Black
Red
3A Fuse
Green
Yellow
White
Transducer
Transducer
5