Rigol DG1000 Series Quick Manual

Rigol DG1000 Series Quick Manual

Dual-channel function/arbitrary waveform generator
Hide thumbs Also See for DG1000 Series:

Advertisement

RIGOL
Quick Guide
DG1000 Series
Dual-Channel Function/Arbitrary
Waveform Generator
Jul. 2012
RIGOL Technologies, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DG1000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Rigol DG1000 Series

  • Page 1 RIGOL Quick Guide DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator Jul. 2012 RIGOL Technologies, Inc.
  • Page 3: Guaranty And Declaration

    RIGOL products are protected by patent law in and outside of  P.R.C. RIGOL reserves the right to modify or change parts of or all the  specifications and pricing policies at company’s sole decision. Information in this publication replaces all previously ...
  • Page 4: Safety Notices

    If you suspect damage occurs terminal of power cord to the to the instrument, please do a Protective Earth terminal inspection by RIGOL before any inputs or outputs. authorized personnel. Observe all Terminal Keep Well Ventilation...
  • Page 5 RIGOL Do Not Operate in an temperature or damages to the Explosive Atmosphere device. So please keep well ventilated and inspect the In order to avoid damages to intake and fan regularly. the device or personal injuries, it is important to operate the...
  • Page 6: Safety Terms And Symbols

    RIGOL Safety Terms and Symbols Terms in this Manual. These terms may appear in this manual: WARNING Warning statements indicate the conditions or practices that could result in injury or loss of life. CAUTION Caution statements indicate the conditions or practices that could result in damage to this product or other property.
  • Page 7: Document Overview

    User Interface  Quick Start  Care and Cleaning  DG1000 series Function/Arbitrary Waveform Generator includes DG1022, DG1022A and DG1022U. In this manual, DG1022 is taken as an example to introduce the using method of the generator. Quick Guide for DG1000...
  • Page 8: Table Of Contents

    RIGOL Contents Guaranty and Declaration ..........I Safety Notices ..............II Safety Terms and Symbols ..........IV Document Overview ............V Primary Inspection ............1 General Inspection ............1 Instrument Inspection ..........2 Accessories Inspection ..........3 Handle Adjustment ............4 Device Connection .............
  • Page 9: Primary Inspection

    2. Inspect the instrument. The front/rear panel are shown as follows. In case of any damage, or defect, or failure, notify your RIGOL Sales Representative. 3. Check the accessories. The standard accessories supplied with the instrument are listed as follows.
  • Page 10: Instrument Inspection

    RIGOL Instrument Inspection Mode/ Direction CH2 Output/ Counter Input Functions Key and USB Host Buttons Knob Output Channel Power Local/ Menu Wave Buttons Switch Button View Buttons Selection Output Buttons Keyboard 10MHz In Sync Out Fuse Socket Power Socket Power Switch...
  • Page 11: Accessories Inspection

    RIGOL Accessories Inspection 1. Standard Accessories A Power Cord A Quick Guide A CD* Note*: The CD includes an User’s Guide and application software. 2. Optional Accessories 40 dB Attenuator Power Amplifier BNC Cable BNC-Alligator Clip Cable USB Cable Note: Pictures above are for a reference merely, the actual items may be different.
  • Page 12: Handle Adjustment

    RIGOL Handle Adjustment Adjust the handle of DG1000 to make the instrument locate in a stable and best observation position. Adjustment Method: Grip the handle by the sides and pull it outward. Then, take it rotate to the desired position.
  • Page 13: Device Connection

    1. Check if the power cord is normally connected and the power switch on the rear panel has been turned on. 2. Check if the fuse is intact, or esle please replace it. 3. If the instrument still cannot be started, contact RIGOL for help. Quick Guide for DG1000...
  • Page 14 RIGOL USB Connection USB Host: This port is used to transfer data when external USB device connects to the generator regarded as a “Host” device. For example, connect a USB flash device for data storage. USB Device: This port is used to transfer data when external USB device connects to the generator regarded as a “Slave”...
  • Page 15: User Interface

    RIGOL User Interface DG1000 offers three display modes, which can be switched by button on the front panel. Menu Mode (Single Channel) Parameter Current Output Display Channel Configuration State Waveform Menu Graph Mode (Single Channel) Current Channel Parameter Display State...
  • Page 16: Quick Start

    RIGOL Quick Start Waveform Settings DG1000 can generate Basic, Arbitrary, Modulated, Sweep and Burst Waveforms. 1. Basic/Arbitrary Waveform Settings The instrument is available to output 5 kinds of basic waveforms: Sine, Square, Ramp, Pulse and Noise. Besides, it has 48 kinds of built-in arbitrary waveforms and provides 10 nonvolatile storage positions to store arbitrary waveforms defined by users.
  • Page 17 RIGOL Setting methods of other waveforms are the same as the example above. All the parameters permitted to be set are listed in the following table. Table 1 Parameters of basic/arbitrary waveforms Waveforms Parameters Frequency/Period, Amplitude/High Level, Sine Offset/Low Level, Phase...
  • Page 18 RIGOL Press to switch the interface to graph mode: Figure 9 AM setting interface under graph display Setting method of other waveforms are the same as the example above. All the parameters permitted to be set are listed in the following table.
  • Page 19 RIGOL Press to enter sweep waveform setting interface as follows. Thereinto, parameters as Linear/log, Start/Center, Stop/Span, Time and Trigger are allowed to be set. Figure 10 Sweep waveform setting interface 4. Burst Waveform Settings Various burst waveforms can be generated by CH1 of DG1000 in burst mode.
  • Page 20: Parameter Input

    RIGOL Parameter Input To input parameters, you need to use the direction keys and knob, in connection with the numeric keyboard on the front panel. Figure 12 Direction keys and knob Figure 13 Keyboard Direction Keys Switch the digital of a numerical value or the storage position of arbitrary waveform/setting files.
  • Page 21: Output Setting

    RIGOL Output Setting The two yellow buttons located at the right of front panel shown as follows are for controlling the channels output and counter input: CH2 Output/Counter Input Connector CH1 Output Connector Figure 14 Channel /Counter Connector Channels output Connect the connector shown above with an external device by ...
  • Page 22: Store And Recall

    RIGOL Store and Recall In order to store, recall or delete arbitrary waveform/setting files in DG1000 or USB storage device, please use the Store/Recall function. Press to enter Store/Recall setting interface: Figure 15 Store/Recall setting interface Table 3 Parameters under the store and recall function...
  • Page 23: Utility System

    RIGOL Utility System Press to enter utility system setting interface. Figure 16 Utility system setting interface Table 4 Parameters of utility system Parameters Explanations Sync On Enable/disable the Sync Signal of CH1 through Sync Off the [Sync Out] connector on the rear panel.
  • Page 24: Help System

    With built-in help system, users can get information for every button on the front panel by pressing corresponding button for a few time. In addition, press to enter the help topics for common operations and information of RIGOL Technology Support. Figure 17 Help information interface Select Current Page...
  • Page 25: Care And Cleaning

    RIGOL Care and Cleaning General Maintenance Do not store or leave the instrument in where it will be exposed to direct sunlight for long periods of time. Caution To avoid damages to the instrument, do not expose it to liquids which have causticity.