Controlling the Monitor with a PC (RS-232C)

You can control this monitor from a PC via RS-232C (COM
port) on the PC.
You can also connect multiple monitors via a daisy chain by
using a PC. By assigning ID numbers to each monitor (see
page 31), you can make input mode selection/adjustment or
can check the status of a specific monitor.
TIPS
• To control the monitor via RS-232C, set RS-232C/
LAN SELECT to RS-232C, and STANDBY MODE to
STANDARD.
• You cannot use RS-232C and LAN control simultaneously.

PC connection

nOne-to-one connection with a PC
Connect with RS-232 straight cable between the PC's COM
port (RS-232C connector) and the RS-232C input terminal on
the monitor.
RS-232C
input terminal
nDaisy chain connection...
PN-U553/PN-U473/PN-U423 monitors can be connected
together in a daisy chain connection.
Connect with RS-232 straight cable between the PC's COM
port (RS-232C connector) and the RS-232C input terminal on
the first monitor.
Next, connect RS-232 straight cable to the first monitor's
RS-232C output terminal and to the second monitor's
RS-232C input terminal. Connect in the same way to the third
and subsequent monitors.
Up to 25 monitors can be connected. (Depending on the
length of the cable used and the surrounding environment.)
Second monitor
RS-232C
output terminal
RS-232 straight cables (commercially available)
30
E
To COM port
RS-232 straight cable
(commercially available)
Advanced operation
First monitor
RS-232C
input terminal
To COM port

Communication conditions

Set the RS-232C communication settings on the PC to match
the monitor's communication settings as follows:
Baud rate
Data length
Parity bit

Communication procedure

nCommand format
When a command is sent from the PC to the monitor, the
monitor operates according to the received command and
sends a response message to the PC.
C1
C2
Command field
(4 prescribed
alphanumerical characters)
PC
Example: VOLM0030
VOLM
* Be sure to input 4 characters for the parameter. Pad with
spaces (" ") if necessary.
("
" is a return code (0D
Wrong : VOLM30
Right
: VOLM
Do not use spaces for MPOS, DATE, and SH01 through
SH07. Specify parameters using a specified number of
characters.
Example: MPOS010097
If a command has "R" listed for "DIRECTION" in the
"RS-232C command table" on page 34, the current value can
be returned by using "?" as the parameter.
Example:
VOLM ? ? ? ?
30
* If an ID number (see page 31) has been assigned
(For example, ID number = 1).
VOLM
PC
30
001
9600bps
Stop bit
8 bits
Flow control
None
C3
C4
P1
P2
P3
Parameter field
(4 character string comprised of:
0-9, +, -, space, ?)
30
, 0A
or 0D
))
H
H
H
30
From PC to monitor (How much
is current volume setting?).
From monitor to PC (Current
volume setting: 30).
?
From PC to monitor.
From monitor to PC.
1 bit
None
Return code
P4