Initialization (Reset)/Functional Restriction Setting (FUNCTION)

You can return the settings to their factory-preset values and
restrict operations.
SIZE
1. Hold
down until "F" appears in the upper left
corner of the screen.
2. While "F" appears, press
order.
FUNCTION
ALL RESET
ADJUSTMENT LOCK
OSD DISPLAY
LED
3. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
(The settings in COMMUNICATION SETTING are
retained.)
ENTER
Press
, select ALL RESET, and then press
After initialization, turn the main power switch off and
then back on.
ADJUSTMENT LOCK
You can disable operations on the monitor and the
remote control unit that use buttons.
OFF ...Enables operation.
ON .....Disables all operations other than turning power
on/off and FUNCTION.
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON ................. Shows menus, modes, and messages.
OFF ............... Hides menus, modes and messages.
LED
Specifies whether to light the power LED.
RETURN
4. Press
to return to the normal screen.
TIPS
• Even if LED is set to OFF, the power LED lights when a
temperature alert occurs.
,
,
,
in that
OFF
ON
ON
OK...[ENTER] BACK...[RETURN]
ENTER
.