CHOKE REPLACEMENT (See Fig 17)
1. Remove the pressure control cover and screws.
2.
Remove the grounding screw (312) and remove the
lead. Loosen the appropriate screw on the terminal
strip (336) and discornect the yellow/green choke
lead.
Use
3.
the M8 wrench to remove the upper nut and
lockwasher (337, U S ) on the outside of the
pressure control box.
4. Remove the old choke (309) and install a new one in
the reverse order of disassembly.
VARISTOR
REPLACEMENT (See Figs 18
WARNING
Relief Procedure Warning on page 17 to reduce
the risk of a fluid injection injury, splashing in the
eyes or on the skin, injury from moving parts, or
1.
Remove the control box screws and cover.
two
2.
Remove the
'
harnesses (318, 319) and the old varistor from the
(302).
ONlOFF switch
Trim the leads on the new varistor (339) to 28.5 mm
3.
(1-118 in.). Turn each lead outward to form a loop
is
that
large enough for the screws
through.
4.
Place a wiring harness on each screw, then place a
loop of the varistor leads on each screw and thread
the screws into the switch.
5.
Wrap the varistor under the switch.
8
19)
(A$).
screws
the wiring
(A,
8) to pass
Fig 17
n
FRONTVIEW
n
SIDEVIEW
21
307-671