Follow these steps to recover the connection:
1. Switch the print server's DIP switch to DIAG.
2. On your laptop, create a new profile using the wireless PCCARD/PCMCIA's
management program. The settings in this profile must correspond with the
print server's Ad Hoc settings, described in Default Ad Hoc settings in the Print
Server, on page 36. Make sure a connection is established with the print
server.
Ad Hoc settings in print server and corresponding settings in laptop's WLAN management
3. In the print server's web interface, configure all wireless settings under Setup
| Wireless according to your WLAN settings (Wireless mode, WEP encryption,
WEP keys, etc.). Click Save and Restart.
These changes will not affect settings when the print server is in DIAG Mode.
The changes will take place when the DIP switch is switched to NORMAL and
the print server is re-powered.
4. Switch the print server's DIP switch back to Normal mode and re-power the
print server (disconnect then reconnect the external power supply).
5. On your laptop, access the previous profile used before losing contact with
the print server and reactivate it. You should now be able to make contact
with the print server again.
Appendix 3: Troubleshooting