Owner's Information
Carefully remove all packaging and
transit protection from the heater before
installation. Dispose of the packaging
responsibly using re-cycling facilities
where they exist.
Specifications and materials may change without notice.
Effective for all 25L and 50L electric storage water heaters manufactured and sold after 1st May 2011.
RIN3699
023334
Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RIN25E24P

  • Page 1: Installation Details

    Owner’s Manual 25 and 50 Litre Electric Storage Water Heater Models: RIN25E24P RIN50E24P RIN50E36 Installation Details Owner’s Information Carefully remove all packaging and transit protection from the heater before installation. Dispose of the packaging responsibly using re-cycling facilities where they exist.
  • Page 2: Table Of Contents

    Owner’s Manual 25L and 50L Electric Storage Water Heaters Contents Installation Details Plumbing Connections Electrical Connection Specifications Operating Instructions Safety Information Service Information Troubleshooting RIN3699 023334 Rev. A...
  • Page 3: Installation Details

    Owner’s Manual 25L and 50L Electric Storage Water Heaters Installation Details Installation Requirements Water Supply Pressure This water heater must be installed This water heater is designed for direct by a licensed tradesperson, and in connection to water supply pressures accordance with •...
  • Page 4 Owner’s Manual 25L and 50L Electric Storage Water Heaters Installation Details Location We recommend a plinth be installed The water heater should be located as under the water heater where the close as possible to the most frequently water heater is subjected to wet used hot water outlet.
  • Page 5: Plumbing Connections

    Owner’s Manual 25L and 50L Electric Storage Water Heaters Plumbing Connections blocked. It is normal for the PTR valve Pressure & Temperature Relief Valve to leak a small amount of water during The Pressure & Temperature Relief Valve heating cycles. is supplied loose with the water heater.
  • Page 6 Owner’s Manual 25L and 50L Electric Storage Water Heaters Plumbing Connections Hot Water Connection Temperature Protection The hot water pipe should be connected Water heaters can produce very hot to either of the RP¾/20 sockets marked water. To reduce the risk of scald injury, OUTLET at the top of the unit.
  • Page 7: Electrical Connection

    Owner’s Manual 25L and 50L Electric Storage Water Heaters Electrical Connection This water heater is designed for Danger: The operation of the thermal single phase 240V A.C supply only. cut-out indicates a possibly dangerous The electrical connection must situation. Do NOT reset the thermal comply with Local Supply Authority cutout until the water heater has been Regulations and AS/NZS3000.
  • Page 8: Specifications

    Owner’s Manual 25L and 50L Electric Storage Water Heaters Specifications Nominal Dimensions Specifications Total Height (A) Storage Capacity (L) Total Width (B) Hot Water Delivery (L) Outlet Height (C) Net Weight Empty (kg) Inlet Height (D) Element Sizes (kW) 2.4, 3.6 Electrical Entry (E) Relief Valve: Pressure (kPa)
  • Page 9: Operating Instructions

    Rinnai supplier. use of the appliance by a person Water can also be very corrosive, the responsible for their safety.
  • Page 10: Safety Information

    Owner’s Manual 25L and 50L Electric Storage Water Heaters Safety Information Warning Important For safe performance, this water heater The PTR Valve and its drain outlet pipe is fitted with: must not be sealed or blocked. It is normal for the PTR valve to leak a small 1.
  • Page 11: Service Information

    Turn carried out by your local Rinnai agent. on the water supply. The service should include the following: vii. Flush the heater until clear water appears.
  • Page 12: Troubleshooting

    For example, if you have the problem has not been identified, a 315 litre storage tank and you please contact Rinnai on 1300 555 545. are using 450 litres of water it is possible that there will be certain...
  • Page 13 Steady flow (PTR) – more than 20L per This may be caused by excessive water supply pressure, a faulty Pressure & Temperature Relief Valve or a faulty thermostat. Turn off the electricity supply and contact Rinnai. RIN3699 023334 Rev. A...
  • Page 14 WARRANTY AND A GUARANTEE TO REPLACE YOUR HOT WATER Replacement Guarantee UNIT IF THE INNER CYLINDER FAILS 4. If an inner cylinder fails on a Rinnai WITHIN 5 YEARS. hot water unit within a further 4 years The terms of the Warranty and...
  • Page 15 Rinnai office; or unit other than by an approved b. more than 25 kilometres from a Rinnai agent or a Technician of a Rinnai agent, gas or electricity utility approved by Rinnai.
  • Page 16 Rinnai: To the extent permitted by law, Rinnai will not be liable for any loss a. the replacement of the hot water or damage to furniture, carpets, unit;...
  • Page 17 Owner’s Manual 25L and 50L Electric Storage Water Heaters RIN3699 023334 Rev. A...
  • Page 18 Fax: (03) 9271 6622 Tel: 1800 000 340 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our Hot Water Service Line.