P3 Cruiser Owner's Manual- Model GB-106
Possible causes for the main circuit breaker to trip
• "Run-down" batteries.
• Over exerting the motor.
Possible solutions:
• Recharge your batteries.
• If the problem persists, have Planet Mobility "load test" the batteries to assure they are not
damaged.
• If the problem persists, assure your battery charger is operating properly.
Resetting the Main Circuit Breaker
If the main circuit breaker trips as a result of "run-down" batteries or because of a temporary
overload, reset the circuit breaker using the following directions:
1. Wait 5 minutes to allow the motor and electronics board to cool, or return to "normal"
operating temperature.
2. Press in on the main circuit breaker reset button.
!
WARNING: BE SURE YOU REMOVE THE KEY FROM THE KEY RECEPTACLE BEFORE RESETTING
YOUR SCOOTER.
NOTE: If the main circuit breaker continues to trip, there is an underlying electrical fault that
needs professional attention. Please contact Planet Mobility.
NOTE: Do not reset your main circuit breaker repeatedly. You must correct the underlying
problem. Failure to correct the problem could cause injury or damage and will void the warranty.
Page 22