22 electrolux

TECHNICAL DATA

Hob dimensions
Width:
Length:
Hob recess dimensions
Width:
Length:
Heat input
Rapid burner:
Auxiliary burner:
TOTAL POWER:
Gas burners
BURNER
NOR-
MAL
POWER
Auxiliary burn-
er
Rapid burner
2.9 (nat.
gas)
2.7 (LPG)
Injectors only for Russia NATURAL GAS G20 - 13 mbar
BURNER
Auxiliary burner
Rapid burner

ENVIRONMENT CONCERNS

The symbol
on the product or on its
packaging indicates that this product may
not be treated as household waste. Instead
it should be taken to the appropriate
collection point for the recycling of electrical
and electronic equipment. By ensuring this
product is disposed of correctly, you will
help prevent potential negative
consequences for the environment and
human health, which could otherwise be
290 mm
520 mm
270 (0/+1) mm
490 (0/+1) mm
2.9 kW
1.0 kW
G20 (2H) 20 mbar =
3.9 kW
G30/G31 (3B/P)
30/30 mbar = 269 g/h
RE-
DUCED
POWER
kW
kW
1.0
0.33
0.75
NORMAL POW-
ER
kW
0.9
1.8
Electric supply:
Gas connection:
Category:
Gas supply:
Appliance class:
By-pass diameters
Burner
Auxiliary
Rapid
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
inj. 1/100
m³/h
mm
70
0.095
119
0.286
REDUCED
POWER
kW
0.33
0.75
caused by inappropriate waste handling of
this product. For more detailed information
about recycling of this product, please
contact your local council, your household
waste disposal service or the shop where
you purchased the product.
230 V ~ 50 Hz
G 1/2"
II2H3B/P
G20 (2H) 20 mbar
Ø By-pass in 1/100
mm.
LPG
(Butane/Propane) G30/G31
(3B/P) 30/30 mbar
inj. 1/100
mm
G30
30
mbar
50
73
86
204
NORMAL POWER
inj. 1/100
80
120
3
28
42
g/h
G31
30
mbar
71
200
m³/h
0.095
0.191