B Rick I Nstallation - Lennox Hearth Products Striker C160 Installation And Operation Manual

Epa certified wood-burning fireplace insert
Table of Contents

Advertisement

Brick Installation
s
™ C/a160 B
triker
CAUTION: Wear gloves during brick installation in
case of sharp edges behind the stove.
Note: Installation of baffle bricks and ceramic blanket is
much easier when you can still access the flue outlet, as in
before installing the insert. Be sure the insulating blanket
is placed flat on the bricks so as not to block the flue and
that it does not hang out over the front of the baffle. Use
a ruler or a piece of kindling to reach back over the blanket
to be sure it is flat on top of the baffle bricks all the way
back.
1. Install bricks #1-18 in the numbered sequence shown
in Figure 1.
2. Install bricks #19 & 20 into the rear stainless steel
baffle support, See Figures 2 & 3.
3. Next install baffle bricks #21-24 by sliding the back
of each brick over the center tube and support until
the front of the brick clears the front tube and sup-
port. Then lift the front of the brick above the front
support and tube and slide it forward as far as it can
go (very important), it will hit the front of the stain-
less support when it is fully forward. The rear of the
bricks sits on top of bricks #19-20 (Figures 2 & 3).
4. Carefully slip the ceramic blanket up over the front of
the front stainless support and bricks #21-24. Grasp
the front of the blanket and slide it back until the front
of the blanket is flush to the front of the bricks #21-
24 (Figure 3). Shake the blanket gently from side to
side to get it to lie flat. Be sure the ceramic blanket
is directly on top of the baffle bricks and that it does
not hang out past the front of the baffle as shown in
Figure 2, also see note above.
WARNING: IF THE BRICKS AR NOT INSTALLED EXACTLY
AS SHOWN THEY COULD FALL OUT OF PLACE DURING
REFUELING OR BURNING OF THE STOVE CAUSING SERI-
OUS INJURY.
Striker C/A160 Brick Sizes
(see Figures on this page)
A = 4-1/4 x 9"
B = 2-1/4 x 8-7/8"
C = 3-1/2 x 9"
D = 2-1/4 x 9"
Insulating Blanket Size is 1/2" x 11" x 20" and fits on
top of the baffle brick.

i
riCk
nstallation
E = 1-1/2 x 8-7/8"
F = Full Brick"
G = 1-1/2 x 9H = 3-1/2 x 8-7/8"
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Firebrick Diagram
17 D
7
1
F
F
2
F
3
D
11
12
F
15 G
Figure 1
See the following for brick sizes
*Fits against the back of the firebox.
Note: These bricks may be slightly smaller to adjust for steel and fire-
brick tolerances beyond our control. Be sure to measure and mark
bricks with their numbers when removing.
Top View of Baffle Brick
19 C
17 D
22 A
21 F
7
8
9
1
F
A
F
F
2
F
3
Figure 2
D
11
13
12
F
F
A
Side Cut-A-Way View of Firebox
15 G
Ceramic Wool Insulation Blanket
Figure 3
18 B
10
8
9
4
F
A
F
F
5
F
14
13
F
F
A
16 E
Front View
20 H
18 B
24 F
23 F
10
4
F
F
5
F
6
14
D
F
16 E
Stainless Steel
Baffle Support
6
D
19 C
21 F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Striker ca160

Table of Contents