Download Print this page

Goodman 13 SEER GPC13H Specifications page 18

Aire acondicionado embalado
Hide thumbs Also See for 13 SEER GPC13H:

Advertisement

E
P
SPECIFICACIONES DEL
RODUCTO
D
C
IAGRAMA DE
ABLEADO
BK
PU
BL
GR
SA
(IF USED) SEE NOTE 4
YL
GR
WH
C L G N
1
2
4 5
3
WH
SEE NOTE 2
EM
L1
SUPPLY VOLTAGE
208-240/1/60
R
C
T1
C
COMP
S
H
RCCF
S.A.
NOTE #4
IF USED
NOTE #2
L
N
EM
3
G
1
2
208-240
NOTE #4
3
24V
4
5
6
PLF
R
W2
W1
THERMOSTAT
High Voltage:
WARNING
Disconnect all power before servicing or installing this unit. Multiple power sources
may be present. Failure to do so may cause property damage, personal injury, or death.
18
: GPC1360H21AB
PU
BK
BK
PU
1
2
3
C
208
240
TR
BL
24V
BL
RD
GR
YL
RD
BR
WH
BL
PLF
3
YL
H
C
F
RCCF
2
1
PU
RD
L2
T2
C
C
F
CM
2
1
TR
C
1
EM
SEE NOTE #2
2
3
C
Y
G
C
www.goodmanmfg.com
NOTE #3
BL
RD
T2
RD
BK
T1
BK
YL
RD
RD
YL
WH
GR
6
9
5
8
BR
4
7
BR
BK
RD
BK
YL
PU
BR
BK
S
C R
CM
COMP
COMPONENT LEGEND
C
CONTACTOR
CM
CONDENSER MOTOR
COMP
COMPRESSOR
EM
EVAPORATOR MOTOR
GND
EQUIPMENT GROUND
LVJB
LOW VOLTAGE JUNCTION BOX
PLF
FEMALE PLUG / CONNECTOR
RCCF
RUN CAPACITOR FOR
COMPRESSOR AND FAN
SA
START ASSIST
TR
TRANSFORMER
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTOR EQUIPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY.
++ USE N.E.C. CLASS 2 WIRE
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
PU
BK
2
0
L2
8
C
-
SEE NOTE 5
2
L1
4
0
/
1
/
GND
60
LVJB
T
H
YL
Y
E
RD
R
R
GR
G
M
W1
WH
O
S
BR
W2
T
C
BL
A
T
++
CONTROL
BOX
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK
BLACK
BL
BLUE
BR
BROWN
GR
GREEN
OR
ORANGE
PU
PURPLE
RD
RED
WH
WHITE
YL
YELLOW
208-240/1/60 0140G00407
SS-GPC13H-SP

Advertisement

loading

This manual is also suitable for: