7 AC Power Draw and Thermal Dissipation
I-Tech 9000HD AC Current Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Data based on both channels driven.
Idle (sleep mode)
Idle (awake)
1/8th Power Pink Noise
Typical of program material
just at clip.
1/3rd Power Pink Noise
Typical of program material
with severe clipping.
page 46
120VAC
Watts Out
Line Current
Amp Line
Load
120VAC
1.0
2.1
8 Ohms/Ch.
6.6
16 Ohms Bridge
4 Ohms/Ch.
11.6
8 Ohms Bridge
2 Ohms/Ch.
11.5
4 Ohms Bridge
8 Ohms/Ch.
13.6
16 Ohms Bridge
4 Ohms/Ch.
27.6
8 Ohms Bridge
2 Ohms/Ch.
25.0
4 Ohms Bridge
I-T9000HD
208VAC
Watts Out
Per 1A
Per 1A
Line Current
Amp Line
Current
208VAC
Current
1.0
1.7
57.6
4.2
91.2
65.7
7.0
108.8
55.9
6.8
96.5
74.4
8.1
125.3
73.9
16.0
127.2
67.0
14.9
113.5
I-Tech HD Series Power Amplifi ers
230VAC
Watts Out
Per 1A
Line Current
Amp Line
Watts
230VAC
Current
Dissipated
0.95
60
1.6
225
3.8
99.8
392
6.3
120.4
593
6.2
105.3
695
7.4
137.2
579
14.3
141.0
1149
13.6
124.3
1223
Thermal Dissipation
Btu/hr
kcal/hr
205
177
767
660
1338
337
2024
510
2373
598
1977
498
3921
988
4173
1052
Operation Manual