Contents Introduction Extractor version Filter version Electrical connections Safety warnings for electrician Technical details Installation Safety warnings for kitchen unit installer Wall unit mounting Wall mounting Hood operation Safety warnings for user Maintenance and care Opening the grid Grease filter Carbon filter Changing the light bulb Cleaning...
Introduction Extractor version The hood is supplied as an extractor unit and can also be used with a filtering function by fitting activated carbon filters (special accessory). The unit features two outlet holes, one of which A is located on the top of the unit while the other B is located on the rear.
Move the lever L to position A — Fig. 3. EXHAUSTING EXHAUSTING ABLUFT ABLUFT EVACUATION EVACUATION ASPIRANTE ASPIRANTE RECIRCULATION RECIRCULATION UMLUFT UMLUFT RECICLAGE RECICLAGE FILTRANTE FILTRANTE When connecting up the hood using a telescopic wall pipe, you should preferably using an uninflammable outlet hose ABS 120 (120 mm Ø) E-Nr.
Electrical connections Safety warnings for electrician Check that the power supply voltage shown on the rating plate corresponds to the mains supply before proceeding to make any electrical connections. If the unit is supplied ready-fitted with a plug, it can be connected to any easily accessible socket installed in compliance with the regulations in force.
Technical details Dimensions: Height x Width x Depth (in cm) 13 x 59,9 x 51 Weight: Net: 6,9 kg Gross: 7,8 kg Maximum absorbed power: 205 W Motor absorption 1 x 125 W Lighting: 2 x 40 W Length of the cable: 110 cm Fan powers (speed), speed in compliance with DIN 44971 Extractor version:...
Installation Safety warnings for kitchen unit installer When used as an extractor unit, the hood must be fitted with a 120mm diameter hose. If the fumes must be forced out through the wall, you must obtain a MKZ sizable wall exhaust pipe (with external exhaust and air intake), E-Nr.- 610 899 004 (Ø...
Page 9
The national decree on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms. Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm large to avoid the possibility of a depression being created during...
Wall unit mounting Make the holes on the bottom of the cupboard, using the drilling template . From inside the cupboard, insert the 4 supplied screws and tighten them in the appropriate holes on the appliance. — Fig. 4.
Wall mounting Fix the drilling template to the wall. Make 3 Ø 8mm holes in the wall. 2 at points I, 1 as desired at points L. Insert the three Ø 8mm expansion plugs into the wall. Insert 2 5x45 screws at points I but do not tighten them completely.
Hood Operation The hood is fitted with a variable speed motor. The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 15 minutes after you have finished, thus ensuring all cooking odours are eliminated.
Safety warnings for user Never leave a cooking hob or ring on without a pot or pan on top of it, to avoid the possibility of excess heat damaging the unit. Gas, oil or coal cooker flames in particular should never be left uncovered. Special care should be taken when using deep fat fryers since the oil in them can overheat and burst into flames.
The filter should be changed when the fat stains on its inside surface can be seen through the grille holes. The grille should be cleaned with luke warm water and non-abrasive detergent when you change the filter. The grease filter can be ordered from the AEG technical assistance service.
The activated carbon filter should only be used if you want to use the hood in its filtering function. To do this you will need an original AEG activated carbon filter (see special accessories). This filter cannot be cleaned or reused.
Warning Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. Changing the light bulb Disconnect the unit from the mains power supply. Remove the grid.
Special accessories MKZ telescopic wall pipe E-Nr. 610 899 004 outlet hose ABS120 942 118 611 120 mm Ø Synthetic grease filter 942 118 625 Metal grease filter MFF2 942 118 633 Carbon filter KFF 942 118 629 Technical assistance service You are welcome to telephone our technical assistance service (see list of technical assistance centres) whenever you need information or in the unlikely event of a fault.