Electrical connections

Safety warnings for electrician

Check that the power supply voltage shown on the
rating plate corresponds to the mains supply before
proceeding to make any electrical connections. If the unit
is supplied ready-fitted with a plug, it can be connected
to any easily accessible socket installed in compliance
with the regulations in force.
If a fixed connection is required, the hood must be
installed exclusively by an electrician registered with the
local electrical company. The hood should be installed
using an omnipolar switch with contacts that open to at
least 3 mm.
Fused switches can be used for this purpose (with
cartridge fuses that can be extracted from the fuse
holder), as can automatic circuit breakers and contactors
which open to more than 3 mm.
We decline all responsibility for any problems or faults
caused by a failure to observe the above instructions.
Installing the socket directly above the hood or above
the wall unit mounted above the hood offers the
following advantages:
1. The socket cannot be seen.
2. The unit can be disconnected whenever required by
simply taking out the plug.
Electrical connections
220-230 V - using fixed power supply line with plug.
(The unit should only be connected up by an authorized
electrician).