Conversion From Natural Gas To Lpg - AEG 69802 G Operating Instructions Manual

Hide thumbs Also See for 69802 G:
Table of Contents

Advertisement

Instructions for the Installer

Conversion from Natural Gas to LPG

IMPORTANT
The replacement/conversion of the gas hob should only be undertaken by a competent
person.
It is important to note that this model is designed for use with natural gas but can be
converted for use with butane or propane gas providing the correct injectors are fitted and
the gas rate is adjusted to suit.
Method
# # # # #
1) Ensure that the gas taps are in the 'OFF' position
2) Isolate the hob from the electricity supply
3) Remove all pan supports, burner caps, rings, crowns and control knobs.
4) With the aid of a 7mm box spanner the burner injectors can then be unscrewed and
replaced by the appropriate LPG injectors.
To adjust the gas rate
With the aid of a thin bladed screwdriver completely tighten down the by pass
adjustment screw. Upon completion stick the replacement rating plate on the under
side of the hob.
23